3Com CS/2500 manual Normal Startup, Messages, Boot Problems, Shutting Down

Models: CS/2500

1 116
Download 116 pages 10.75 Kb
Page 46
Image 46

3-8 CHAPTER 3: STARTUP

Normal Startup

If a terminal is attached to the console port, startup messages appear on

Messages

it during the boot process. These messages vary, depending on your boot

 

source. For example, if the firmware’s Initial Boot Source parameter is

 

set to Local Floppy or Floppy then Network on a Model CS/2600,

 

messages similar to the following appear on the console:

 

Series 2000 Power-up

 

CPU - Passed 2Mbyte RAM C3 MMON rev. xyz

 

EC- Passed Station Address- 0800F1B67068

 

SIO - Passed 10 ports

 

..........

 

The server’s Ethernet address and firmware version are displayed along

 

with other startup messages.

 

For more information, refer to Appendix B, “Startup Messages.”

 

If the LEDs or console messages indicate an error, refer to Chapter 6,

 

“Troubleshooting.” If you still cannot resolve the problem, contact 3Com

 

or your network supplier.

 

 

Boot Problems

If the Self Test LED remains on longer than one minute, the unit has

 

failed the test. Contact 3Com or your network supplier.

 

If a terminal is attached to the port designated as the console port, check

 

it for confirmation of the failure. The server may not always be able to

 

report the failure on the console (for example, CPU failure). Report the

 

failure and console messages, if any, to 3Com or your network supplier.

 

Appendix B, “Startup Messages,” provides information on these

 

messages.

 

If the Self Test LED flashes after the self-test diagnostics have run, the

 

communications server is unable to boot its software from the RBCS

 

server. Verify that the RBCS server is properly configured and attached

 

to the network. (Refer to the Remote Boot and Configuration Services

 

User’s Guide for configuration information.) Press the communications

 

server’s reset switch to try again.

Shutting Down

To shut down a communications server, follow these steps:

Page 46
Image 46
3Com CS/2500 manual Normal Startup, Messages, Boot Problems, Shutting Down