| Ref.: |
| |
SpaceWire Router |
| UserManual | |
Issue: | 3.4 | ||
User Manual | |||
Date: | 11th July 2008 | ||
|
|
|
Table 7-8 Read Incrementing Address Characteristics
Action | Supported/ | Maximum number | |
| Not Supported | of bytes | accepted |
|
|
| |
|
|
| - |
NS | - | ||
|
|
| - |
NS | - | ||
|
|
| No |
S | 1064 | ||
|
|
| - |
NS | - | ||
|
|
|
|
Word or byte address |
|
| |
|
|
|
|
Accepted Logical Addresses | 0xFE |
|
|
|
|
|
|
Accepted destination keys | 0x20 at power on |
|
|
|
|
| |
Accepted address ranges | 0x00 0000 0000 – 0x00 0000 0109 |
| |
|
|
| |
Incrementing address | Incrementing address only |
| |
|
|
|
|
The RMAP read incrementing address command is supported in the SpaceWire router. The read incrementing address is used to read a continuous block of registers from the SpaceWire router, e.g. the complete group adaptive routing table can be read in one command or all the status registers for the SpaceWire links can be read in one command.