SpW-10X

Ref.:

UoD_SpW-10X_

SpaceWire Router

 

UserManual

Issue:

3.4

User Manual

Date:

11th July 2008

 

 

 

WARNING

The default timeout intervals of 60-80 µs or 1.3 ms are short. It may be necessary to increase the timeout interval by a configuration command writing to the router control register. When initially prototyping a SpaceWire system it is advisable to set the timeout interval to 1.3 s and then decrease it to an appropriate value once basic system operation has been established.

9.5.4 Error active Register

The error active register address is 259 (0x0000 0103).

The error active register indicates the Error Active bit of the each of the port control/status registers. By reading from this register a network manager can determine which ports currently have errors. This register is also used to clear the error bits of the port control/status registers. To do this a write command is sent to the error active register with bits set for those errors that are to be cleared.

The error active register fields are shown in

Figure 9-6 and described in Table 9-11.

31

30

1

0

 

 

 

 

Error Active Configuration Port

Error Active SpaceWire and External Ports

Not used

Figure 9-6 Error Active Register Fields

Preliminary

120

Page 120
Image 120
Atmel SpW-10X user manual Error active Register, Error Active Register Fields