13. ANOMALIES AND WARNINGS
In this section a list of anomalies and warnings is provided:
13.1 ANOMALIES
The following anomalies are present in the prototype
1.Simultaneous transitions on data and strobe can occur during reset and power up. This may be a problem when operating with legacy
2.When a parity error in a data character the following characters may be received before the link disconnects.
13.2 WARNINGS
Various warnings appear in boxes throughout this document. They are all gathered in this section for convenience.
WARNING
Simultaneous data/strobe transitions can occur during reset and power up. This is not a problem when connected to SpaceWire compliant devices but is a problem when connected to
WARNING
Since LVDS is based on a current loop it should not matter what the supply voltage is to an LVDS device connected to the