In Figure 7-5 the first byte received by the SpaceWire router configuration logic is the port address followed by the destination logical address. Fields which are depicted in bold text are expected values. Fields which are shaded are optional.

 

 

 

 

 

 

 

 

 

First Byte Received

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Config Port Address

 

 

 

 

 

 

 

 

 

 

00h

 

 

 

 

 

 

 

 

 

 

 

Destination Logical Address

Protocol Identifier

Packet Type, Command

Destination Key

 

 

 

FEh

 

01h

Source Path Addr Len

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Source Path Address

Source Path Address

Source Path Address

Source Path Address

 

 

 

 

 

 

 

 

 

 

 

 

 

Source Logical Address

Transaction Identifier (MS)

Transaction Identifier (LS)

Extended Read Address

 

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Read Address (MS)

Read Address

Read Address

Read Address (LS)

 

 

 

00h

 

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Length (MS)

 

Data Length

Data Length (LS)

Header CRC

 

 

 

00h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EOP

 

 

 

 

 

 

 

 

Last Byte Received

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bits in Packet Type / Command / Source Path Address Length Byte

 

 

 

 

MSB

 

 

 

 

 

 

 

 

 

 

LSB

0

 

 

1

0

 

0

1

1

Source Path

Source Path

 

 

Address Length

Address Length

 

 

 

 

 

 

 

 

 

Packet Type

 

 

Command

 

Source Path Address Length

Figure 7-5 Read Incrementing Address Command Format

Table 7-9 Read Incrementing Address Command Packet Fields

Field

Description

Bytes

 

 

 

Config Port

The configuration port address field routes the packet to the configuration

1

Address

port of the router. The configuration port address is always present when

 

 

configuring the SpaceWire Router.

 

 

 

 

Destination

The destination logical address is not used in the SpaceWire Router. The

1

Logical

SpaceWire router accepts packets which have the default destination logical

 

Address

address of 254h (FEh).

 

 

 

 

Protocol

The RMAP protocol identifier is 01h.

1

Identifier

 

 

 

 

 

Command

The command byte indicates a read incrementing packet. The Source path

1

Byte

address length fields are set to the number of source path addresses

 

 

required as defined in section 7.6.9.

 

 

 

 

Preliminary

62