To connect serial devices to the AMX switching system:

NOTE: The AMIQ-SRL module is a DCE device and only supports VT100 terminal emulation.

1.Attach the AMIQ-SRL module to the serial port of the device to be attached.

2.Attach one end of a UTP cable to the RJ-45 connector on the AMIQ-SRL module. Attach the other end of the cable to an RJ-45 server port on the back panel of the AMX switch.

3.Attach the power supply to the power connector on the AMIQ-SRL module. Up to four AMIQ- SRL modules can be powered from a single power supply.

4.Attach the AMIQ-SRL module power supply to an AC wall outlet.

Repeat this procedure for every serial device that will be attached to the AMX switching system. See Using AMIQ-SRL Modules on page 85 for more information about using AMIQ-SRL modules.