Appendices 85
Appendix B: Using AMIQ-SRL Modules
The
AMIQ-SRL module modes
The following modes can be accessed from the
•
•History: This mode enables you to review serial data.
•Configuration: This mode enables you to specify communication parameters, the appearance of the serial data, key combinations for specific actions and macros.
Configuring the AMIQ-SRL module
NOTE: The
Pressing
NOTE: When the Configuration Screen is active, pressing Enter saves changes and returns you to the previous screen. Pressing Esc returns you to the previous screen without saving changes.
Within the Configuration Screen, you can modify the following options:
•Baud Rate: This option allows you to specify the serial port communications speed in bauds per second (BPS). Available options are 300, 1200, 2400, 9600, 19200, 34800, 57600 or 115200. The default value is 9600.
•Parity: This option allows you to specify the serial port communications parity. Available options are EVEN, ODD or NONE. The default value is NONE.
•Flow Control: This option allows you to specify the type of serial flow control. Available options are NONE, XOn/XOff (software) and RTS/CTS (hardware). The default value is NONE. If you select a Baud Rate of 115200, the only available Flow Control is RTS/ CTS (hardware).
•DSR/CD Mode: This option allows you to control the Data Set Ready/Carrier Detect line on your serial interface. Available options are Always on and Toggle. The default value is Always on.
•Enter Sends: This option enables you to specify the keys that are transmitted when Enter is pressed. Available options are <CR> (Enter) or <CR><LF> (Enter - Linefeed).
•Received: This option enables you to specify how the module translates a received Enter character. Available options are <CR> (Enter) or <CR><LF> (Enter - Linefeed).