Current Parameter

Nominal and peak current values are automatically entered for the motor type. For manual tuning only, set the control current limit value to a percentage of the continuous current rating. For example, if your control is rated for 5A continuous current and you desire to limit the output current to 4A, enter 80%. If you wish to use the full output power of the control, enter 100%. Click “Download” when finished.

Figure 5-5 Current Parameter Screen

Velocity Parameter (Refer to Help“Unit Conversion from Linear to Rotary” for more information) Set the velocity parameters of the control:

Refer to “Velocity Parameters (RPM m/s)” at the end of this section.

1.Scale factor - ratio of the input voltage to output speed.

2.Minimum velocity

3.Time to maximum velocity

Click “Download” when finished.

Figure 5-6 Velocity Parameter Screen

MN1851

Operation 5-9

Page 44
Image 44