Sys.mod 1 & Sys.mod 3

Velocity mode Parameters:

Command

Description

Units

Range

Default

E2 / Par. set

VEL.ACC

Queries /updates velocity acceleration

RPM/ms

0

: 7500

 

E / P

 

limits ( time to max. velocity ).

 

 

 

 

 

 

 

 

 

 

 

 

VEL.ADZON

Queries / updates min. velocity in RPM

RPM

0

: Max_RPM

 

E / P

VEL.BW

Queries / updates velocity control band

Hz

10 : 200

 

E / P

 

width

 

 

 

 

 

 

 

 

 

 

 

VEL.CTRL

Queries / updates velocity control type

 

0, 2

 

E / P

VEL.GV

Queries / updates velocity control

 

0

: 32767

 

E / P

 

proportional gain

 

 

 

 

 

 

 

 

 

 

 

 

VEL.GVI

Queries / updates velocity control integral

 

0

: 32767

 

E / P

 

gain

 

 

 

 

 

 

 

 

 

 

 

 

VEL.INRT

Load inertial, set in % of motor inertia

%

0

: 10000

 

E / P

 

MTR.JM

 

 

 

 

 

 

 

 

 

 

 

VEL.LPFA

Bandwidth of single velocity control filter.

Hz

20 : 800

500

E / P

 

 

 

 

 

 

VEL.LPFB

Second Bandwidth of double velocity

Hz

20 : 800

500

E / P

 

control filter (First s. VEL.LPFA).

 

 

 

 

 

 

 

 

 

 

 

 

VEL.LPFMOD

Type of velocity control filter (0: no filter, 1:

0

: 20

0

E / P

 

filter with bandwidth VEL.LPFA, 2: double

 

 

 

 

 

 

filter with bandwidths VEL.LPFA and

 

 

 

 

 

 

VEL.LPFB

 

 

 

 

 

 

 

 

 

 

 

VEL.TRKFCT

Queries / updates velocity control tracking

 

–32768 : 32767

 

E / P

 

factor

 

 

 

 

 

 

 

 

 

 

 

VEL.MXRPM

Queries / updates velocity control MAX

RPM

1000 : (7500)

 

E / P

 

RPM value. The limit for this value is

 

 

 

 

 

 

internally calculated by the Application Bus

 

 

 

 

 

 

Voltage and the Motor Voltage Constant.

 

 

 

 

 

 

Absolute limit for velocity is 7500 RPM.

 

 

 

 

 

 

 

 

 

 

 

VEL.SCAL

Corresponding velocity value to analog

RPM

100 : 32767

 

E / P

 

input voltage VEL.VOLT for setting of

 

 

 

 

 

 

analog input scaling.

 

 

 

 

 

 

 

 

 

 

 

 

VEL.VOLT

Corresponding analog input voltage to

0.1 V

1

: 100

 

E / P

 

velocity value VEL.SCAL for setting of

 

 

 

 

 

 

analog input scaling

 

 

 

 

 

Velocity mode Variables:

Command

Description

Units

Range

Default

E2 / Par. set

VEL.VREF

Queries velocity reference, commanded at

RPM

 

 

– /

 

analog input

 

 

 

 

 

 

 

 

 

 

VREF

 

 

 

 

– /

Velocity mode Methods:

Command

Description

Parameter

Units

Range

VCRST

Velocity controller parameters reset to default values: Pole

 

 

 

 

Placement controller: BW = 20 Hz, TRFCT = 0 , INRT = 0;

 

 

 

 

PI controller: GV, GVI equivalent to Bandwidth 20 Hz

 

 

 

MN1851