Baldor MN1851 manual Peak output current by 1.1% for each 330 feet, Description Unit

Models: MN1851

1 95
Download 95 pages 28.33 Kb
Page 56
Image 56

Specifications Continued

Description

 

Unit

LP4 A02TB

LP4 A05TB

LP4 A07TR

LP4 A15TR

LP4 A20TR

 

 

 

 

 

 

 

 

Input Voltage Range

Nominal

VAC

 

460 @ 60Hz / 400 @ 50Hz

 

 

Minimum

 

 

 

400 / 360

 

 

 

Maximum

 

 

 

528 / 480

 

 

 

 

 

 

 

 

 

 

Input Frequency

 

Hz

 

 

50/60 ± 5%

 

 

 

 

 

 

 

 

 

 

Nominal Output Bus

Nominal

VDC

 

 

565 / 678

 

 

(@ 400 / 460 input)

Minimum

 

 

 

509 / –

 

 

 

Maximum

 

 

 

– / 744

 

 

 

 

 

 

 

 

 

Nominal Phase Current (± 10%)

ARMS

2.5

5

7.5

15

20

Peak Phase Current (± 10%);

ARMS

5

10

15

30

40

2.4s +0.5s/–0s



 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Output Power

KVA

1.9

3.7

5.6

11.2

14.9

 

 

 

 

 

 

 

 

Output Frequency

 

Hz

 

 

0 – 500

 

 

 

 

 

 

 

 

 

 

Efficiency

 

%

 

 

>95

 

 

 

 

 

 

 

 

 

Nominal Switching Frequency

KHz

 

 

8.0

 

 

 

 

 

 

 

 

 

Current Loop Bandwidth

Hz

 

 

1200

 

 

 

 

 

 

 

Velocity Loop Bandwidth

Hz

 

10 to 200 (software selectable)

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

Panel

 

 

 

 

 

 

 

 

 

 

Package Size

 

G

G

G

H

H

 

 

 

 

 

 

 

 

Operating Altitude

 

Feet

To 3300 feet (1000 meters). Derate the continuous and

 

 

(Meters)

peak output current by 1.1% for each 330 feet (100

 

 

 

meters) above 3300 feet.

 

 

 

 

 

Operating Temperature

° C

+0 to 40. Above 40° C, derate the continuous and peak

 

 

 

output current by 2.5% per ° C above 40° C. Maximum

 

 

 

ambient is 50° C.

 

 

 

 

 

 

 

 

 

 

Rated Storage Temperature

° C

 

 

–25 to +70

 

 

 

 

 

 

 

 

Humidity

 

%

 

10% to 90% non-condensing

 

 

 

 

 

 

 

 

Class of Protection (Enclosure)

 

 

 

IP20

 

 

 

 

 

 

 

 

Shock

 

 

 

10G (according to DIN IEC 68–2–6/29)

 

 

 

 

 

Vibration

 

 

1G @ 10 – 150 Hz (according to DIN IEC 68–2–6/29)

 

 

 

 

 

 

 

 

Valid for zero current initial condition.

All values at ambient temperature of 25° C unless otherwise stated.

For safe operation, allow a clearance distance between each control and on all sides of each control.

MN1851

Specifications & Product Data 7-3

Page 56