Baldor MN1851 manual Control Outputs, Encoder Output

Models: MN1851

1 95
Download 95 pages 28.33 Kb
Page 11
Image 11

Control Inputs Opto isolated inputs are single ended, user selectable and active high or low:

Enable

Machine Input 1

Quit

Machine Input 2

Fault Reset

Machine Input 3

Home Flag

Machine Input 4

Trigger

 

Note: Machine Inputs 1–4 allow up to 16 digital preset point to point positions.

Control Outputs

One normally closed relay contact provides a dedicated “Drive Ready” output.

Two opto isolated outputs are single ended, active low and are current sinking. Either output can be assigned to one of the following:

In Position

Machine Input 1

CW Warning

Machine Input 2

CCW Warning

Machine Input 3

Following Error Flag

Machine Input 4

Following Error Warning

I2t Warning

Drive Over Temperature

 

Encoder Output

The motor encoder signals are available at this output connector (1 to 1).

2-2 Product Overview

MN1851

Page 11
Image 11
Baldor MN1851 manual Control Outputs, Encoder Output