General Settings

System Constants

Command

Description

Range

Common

Lev I

LevII

SYS.POWER

Queries dip switch ID, (see DRV.ID)

 

X

 

 

 

 

 

 

 

 

SYS.FBACK

Queries system feedback

0:1

X

 

 

 

(encoder / resolver)as defined by ALTERA

 

 

 

 

 

 

 

 

 

 

SYS.INFO

Queries firmware version with naming and

ASCII letters

X 

 

 

(SYS.VER)

version number as ASCII string

 

 

 

 

 

 

 

 

 

 

SYS.LEVEL

Queries level version

1 : 2

X 

 

 

SYS.OPT

Queries ALTERA option(s)X

0 : 7

X

 

 

SYS.STTS

Most Significant–Word of SYS.STTS gives

(MS-Word of

 

 

 

(COM.ADDR)

control address of (LS–Word s. below).

SYS.STTS)

 

 

 

 

Control Address is set per Dip Switch

 

 

 

 

Firmware versions RES–1.xx, ENC–1.xx SYS.VER is equal to SYS.INFO , downward versions: answer to SYS.VER is unsigned integer version number only

Firmware versions RES–1.xx, ENC–1.xx only (no version)

Basic System Parameters

Motor Parameters (MTR. prefixed)

Command

Description

Units

Range

Default

E2 / Par. set

MTR.IDX

D3S/LinDrive/Lin+Drive Setup library

 

 

Unsign Int.

 

E / P

 

defined Motor Index

 

 

 

 

 

 

 

 

 

 

 

 

MTR.IND

Motor inductance

0.01

H

1 : 65535

 

E / P

MTR.INOM

Motor nominal current

0.1 A

1 : 65535

 

E / P

MTR.IPEAK

Motor peak

0.1 A

1 : 65535

 

E / P

MTR.JM

Motor Inertia

0.01

Kg-cm2

1 : 65535

 

E / P

MTR.MPLS

Motor number of poles

 

 

1 : 65535

 

E / P

MTR.RES

Motor resistance

0.01

Ohm

1 : 65535

 

E / P

MTR.KT

Motor torque constant (torque to RMS

0.001 Nm/A

1 : 65535

 

E / P

 

phase current)

 

 

 

 

 

 

 

 

 

 

 

MTR.KV

Motor bemf constant

V/1000RPM

1 : 65535

 

E / P

MTR.NAME

Motor string name in ASCII characters

 

 

ASCII char.

 

E / P

Drive Parameters (typical DRV. prefixed)

Command

Description

Units

Range

Default

E2 / Par. set

DRV.BUSAPP

Application bus voltage

V

Unsign. Int.

 

E / P

DRV.BUSOV

Application bus over voltage

V

Unsign. Int.

 

E / P

DRV.BUSV

Drive Bus voltage

V

Unsign. Int.

 

E / P

DRV.I2T

I2t warning time

0.01 s

100 : 300

 

E / P

DRV.ID

Drive ID (EEPROM value) to be checked

 

Unsign. Int.

 

E / P

 

against power ID ( dip switch ) in case of

 

 

 

 

 

Version Error ( “U” )

 

 

 

 

 

 

 

 

 

 

DRV.IDX

LinDrive/Lin+Drive Setup library index

 

Unsign. Int.

 

E / P

DRV.INOM

Drive nominal current

0.1 A

Unsign. Int.

 

E / P

DRV.IPEAK

Drivepeak current

0.1 A

Unsign. Int.

 

E / P

B-4 Command Set

MN1851

Page 81
Image 81
Baldor MN1851 manual General Settings System Constants, Basic System Parameters Motor Parameters MTR. prefixed