Baldor MN1851 manual Jog Parameters, Jog.Time, Jog.Type, Jog.Vel

Models: MN1851

1 95
Download 95 pages 28.33 Kb
Page 91
Image 91

Jog

Parameters:

Command

Description

Units

Range

Default

E2 / Par. set

JOG.TIME

Jog time in milliseconds

ms

3432448

 

E / –

 

 

 

 

 

 

JOG.TYPE

0 – continuous, 1 – step, 2 – square wave

0 : 2

 

E / –

 

 

 

 

 

 

JOG.VEL

Jog velocity in RPM, limited to maximum

 

VEL.MXRPM

 

E / –

 

velocity VEL.MXRPM.

 

 

 

 

Methods:

Command

Description

Parameter

Units

Range

JOG

Commanding a Jog according to JOG.* parameters, with

Direction

“+”, “–”

JS

Stops jog and returns to previous operation mode

B-14 Command Set

MN1851

Page 91
Image 91