Specifications

Description

 

Unit

LPx

LPx

 

LPx

 

LPx 

 

LPx 

 

LPx 

 

LPx 

 

 

 

A02T

A05T

 

A07T

 

A02S

 

A05S

 

A010S

 

A015S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltage Range

Nominal

VAC

 

115

 

 

 

 

 

230

 

 

 

Minimum

 

 

92

 

 

 

 

 

184

 

 

 

Maximum

 

 

132

 

 

 

 

 

265

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Frequency

 

Hz

 

 

 

 

50/60 ± 5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Output Bus

Nominal

VDC

 

160

 

 

 

 

 

320

 

 

(@ 115 / 230 input)

Minimum

 

 

88

 

 

 

 

 

176

 

 

 

Maximum

 

 

180

 

 

 

 

 

360

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Phase Current (± 10%)

ARMS

2.5

5.0

 

7.5

 

2.0

 

5.0

 

10

 

15

Peak Phase Current (± 10%); for

ARMS

5

10

 

15

 

4

 

10

 

20

 

30

2.4sec (+0.5s/–0sec) maximum 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Output Power

 

KVA

1.01

2.17

 

2.99

 

0.87

 

2.17

 

4.33

 

5.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Frequency

 

Hz

 

 

 

 

 

0 – 500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency

 

%

 

 

 

 

>95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Switching Frequency

KHz

 

 

 

 

8.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Current Loop Bandwidth

Hz

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Velocity Loop Bandwidth

Hz

 

 

10 to 200 (software selectable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

 

 

 

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Package Size

 

A

B

 

C

 

E

 

E

 

E

 

E

 

 

 

 

 

 

 

 

 

 

Operating Altitude

 

Feet

To 3300 feet (1000 meters). Derate the continuous and

 

 

(Meters)

peak output current by 1.1% for each 330 feet (100

 

 

 

 

meters) above 3300 feet.

 

 

 

 

 

 

 

 

Operating Temperature

° C

+0 to 40. Above 40° C, derate the continuous and peak

 

 

 

output current by 2.5% per ° C above 40° C. Maximum

 

 

 

ambient is 50° C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Storage Temperature

° C

 

 

 

 

–25 to +70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

 

%

 

 

10% to 90% non-condensing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Class of Protection (Enclosure)

 

 

 

 

 

 

IP20

 

 

 

 

 

 

 

 

 

 

 

Shock

 

 

 

10G (according to DIN IEC 68–2–6/29)

 

 

 

 

 

Vibration

 

 

1G @ 10 – 150 Hz (according to DIN IEC 68–2–6/29)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid for zero current initial condition.

These specifications also apply to model LPxAxxP except it has DC input (no AC input). All values at ambient temperature of 25° C unless otherwise stated.

For safe operation, allow a clearance distance between each control and on all sides of each control.