System Variables

General Variables:

Command

Description

Units

Range

Default

E2 / Par. set

DRV.LIFE

Drive life time.

Hrs

Unsign.Word

 

E / –

 

 

 

 

 

 

SYS.STTS

Queries system status as a double word,

Long Word

 

– /

 

where Word High word is drive address

 

 

 

 

 

(set by Dip switches)

 

 

 

 

 

Low word: bit array “OR”ed with system

 

 

 

 

 

status:

 

 

 

 

 

0x0001: Disable SW

 

 

 

 

 

0x0002: Disable HW

 

 

 

 

 

0x0004: CW

 

 

 

 

 

0x0008: CCW

 

 

 

 

 

0x0010: Fault exists

 

 

 

 

 

0x0020: Warning exits

 

 

 

 

 

0x0040: Hold mode

 

 

 

 

 

0x0080: Burn in Status

 

 

 

 

 

0x0100: Jog Status

 

 

 

 

 

0x0200: Enable

 

 

 

 

 

0x0400: Jog Non Zero Velocity

 

 

 

 

 

0x0800: n/a

 

 

 

 

 

0x1000: HW source for Disable HW:

 

 

 

 

 

0x2000: PLC active

 

 

 

 

Queries / modifications of Fault Listing Variables:

Command

Description

Units

Range

Default

E2 / Par. set

FAULT

Gets system fault string list, response is

 

 

– /

 

multiple string X1

 

 

 

 

 

 

 

 

 

 

FLT

Gets system fault string list, response is

X1

 

– /

 

error numberX1

 

 

 

 

 

 

 

 

 

 

LOG, LG

Gets system fault log list X1

X1

 

– /

LG

Gets system fault log number list X1

 

 

– /

WRN

Gets system warning list as multiple strings

 

 

– /

SYS.FAULT

Queries system fault as ID of the most

 

 

– /

 

significant fault

 

 

 

 

 

 

 

 

 

 

SYS.WRN

Queries system warnings. The most

 

 

– /

 

important warning will be reported as ID

 

 

 

 

X1 Possible Faults

 

X1 Fault

Display

Description

 

1

“USER ERROR”

PLC user generated error. Displays ’9’.

 

2

“OVERCURRENT”

over current. Displays ’3’.

 

3

“OVERVOLTAGE”

3– bus over voltage. Displays ’1’.

 

4

“FEEDBACK”

resolver/encoder position feedback error. Displays ’5’.

 

5

“POWER_FAIL”

power fail. Displays ’2’.

 

 

 

 

 

 

6

“BPS”

BPS fail. Displays ’2’.

 

 

 

 

 

 

7

“OVER_15_VOLTAGE”

± 15v over voltage. +15v line is more then 17v or –15v line is

 

 

 

more than –17v. Displays ’4’.

 

 

 

 

 

 

8

“UNDER_15_VOLTAGE”

± 15v under voltage. +15v line is less then 12v or –15v line is

 

 

 

less than –12v. Displays ’4’.

 

 

 

 

 

 

9

“EEPROM_ERROR”

N.I

 

10

“EPROM_ERROR”

N.I

 

11

“RAM_ERROR”

RAM integrity error. Displays ’9’.

 

 

 

 

 

B-8 Command Set

MN1851

Page 85
Image 85
Baldor MN1851 manual System Variables General Variables, Queries / modifications of Fault Listing Variables