PLC Parameters:

Command

Description

Units

Range

Default

E2 / Par. set

PLC.LINE

Defines PLC statement :IF [input]=TRUE,

num: 0 : 12

PLC disabled,

 

E / P

 

THEN [action] set/started, with syntax

action: s. left

all lines:

 

 

 

PLC.LINE [num] [action] [input] [num]

lines:

input = false

 

 

 

[action] – PLC line number, and string

input: s. left

 

 

 

 

parameter for PLC action, fixed to line

lines:

 

 

 

 

number:

 

 

 

 

 

0

“ENABLE” (PLC enable)

 

 

 

 

 

 

 

 

 

 

1

“MAO1” (Digital Input MAO1)

 

 

 

 

 

2

“MAO2” (Digital Input MAO2)

 

 

 

 

 

3

“MAO3” (Digital Input MAO3, if available)

 

 

 

 

 

4

“MAO4” (Digital Input MAO4, if available)

 

 

 

 

 

5

“RELAY” (

 

 

 

 

 

6

“USRERR” (Error “9”)

 

 

 

 

 

7

“FRST” (Fault Reset)

 

 

 

 

 

8

“DISA” (Disable active, s. 0)

 

 

 

 

 

9

“DISP” (Disable active, s. 0)

 

 

 

 

 

10 “HOLD” (Hold–status, s. 0)

 

 

 

 

 

11 “JOG” (JOG function, s. 0)

 

 

 

 

 

12 “GEAR”

 

 

 

 

 

[input] – string parameter with enumerated

 

 

 

 

 

values:

 

 

 

 

 

 

“FALSE”: Always false, i.e. switched off

 

 

 

 

 

 

“CW”, “CCW”: Hardware or Software

 

 

 

 

 

 

Limit Switches

 

 

 

 

 

 

“MAI1”, “MAI2 ”: Digital Inputs

 

 

 

 

 

 

“MAI3”, “MAI4”: Digital Inputs (if

 

 

 

 

 

 

available)

 

 

 

 

 

 

“DRVOT”,“MTROT”: Drive respectively

 

 

 

 

 

 

motor overtemperature

 

 

 

 

 

 

“I2tWRN”: I2T–warning (error “7”)

 

 

 

 

 

 

“TRUE”: Always true, i.e. switched ON

 

 

 

 

 

 

“INPOS”, “FEWRN”, “FEFAT”: Flags of

 

 

 

 

 

 

Position Controller in position,

 

 

 

 

 

 

following error warning, following error

 

 

 

 

 

 

limit (s. 0)

 

 

 

 

 

 

BADMOV: Not initialized motion buffer

 

 

 

 

 

 

line commanded (s. 0)

 

 

 

 

 

 

“MOTRDY”, “MOTNRDY”: Positioning

 

 

 

 

 

 

finished respectively in process

 

 

 

 

 

 

 

 

 

 

 

Note: Choice of Inputs and Outputs is not completely available in all configurations

Variables: NONE

PLC Methods:

Command

Description

Parameter

Units

Range

PLC

Enables (“on”) / disables (“off”) / clears and disables (“clr”)

“on”, (“off”), “clr”

 

 

 

PLC. PLC on and off command is stored in PLC buffer line

 

 

 

 

0.

 

 

 

B-6 Command Set

MN1851

Page 83
Image 83