Baldor MN1851 manual Position Controller Position Controller Parameters, Variables

Models: MN1851

1 95
Download 95 pages 28.33 Kb
Page 92
Image 92

Position Controller

Position Controller Parameters:

Command

Description

Units

Range

Default

E2 / Par. set

POS.FFA

Queries/updates acceleration FF factor

25 : 100

 

E / P

 

unsigned integer ranged 0..100

 

 

 

 

 

 

 

 

 

 

POS.FFTYPE

Queries / updates FF type with position

0 : 2

 

E / P

 

controller redesign 0 – FF none, 1 –

 

 

 

 

 

velocity FF, 2 – acceleration FF

 

 

 

 

 

 

 

 

 

 

POS.FFV

Queries / updates velocity FF factor

25 : 100

 

E / P

 

unsigned integer ranged within 0..100

 

 

 

 

 

 

 

 

 

 

POS.KP

Queries / updates position gain unsigned

25 : 100

 

E / P

 

integer ranged within 25.. 200

 

 

 

 

 

 

 

 

 

 

POS.FEWRN

Queries / updates FE warning limits

1/4096

–32768 : 32767

 

E / P

 

resolver: 1/4096 of revolution,

(resolver)

 

 

 

 

encoder: 1/(4*SYS. encres) of revolution

1/(4*SYS.

 

 

 

 

integer, > 0 (< 0: disabled)

encres)

 

 

 

 

 

encoder

 

 

 

 

 

 

 

 

 

POS.FEFAT

Queries / updates FE fatal limits 1/4096 of

1/4096 of

–32768 : 32767

 

E / P

 

revolution, integer,

revolution

 

 

 

 

 

 

 

 

 

POS.IPOS

Queries / updates FE in position limits

1/4096 of

–32768 : 32767

 

E / P

 

1/4096 of revolution, integer, > 0 (< 0:

revolution

 

 

 

 

disabled)

 

 

 

 

 

 

 

 

 

 

Variables:

Command

Description

Units

Range

Default

E2 / Par. set

POS.MPFE

Queries maximum position following error

1/4096 of rev.

 

 

– /

MPFE

 

 

 

 

– /

 

 

 

 

 

 

POS.PFE

Queries position following error

1/4096 of rev.

 

 

– /

 

 

 

 

 

 

PFE

 

 

 

 

– /

 

 

 

 

 

 

PREF

Queries for position reference

1/4096 of rev.

 

 

– /

 

 

 

 

 

 

POS.REF

Queries position controller reference,

1/4096 of rev.

 

 

– /

 

1/4096 of revolution

 

 

 

 

POS.FEST

Returns follow error status: 0 – normal,

0 : 3

 

– /

 

1 – in position, 2 –warning, 3 – error

 

 

 

 

 

 

 

 

 

 

FEST

 

 

 

 

– /

Methods:

Command

Description

Parameter

Units

Range

PRST

Resets position following error

MN1851

Command Set B-15

Page 92