After the motor and control are selected, click the General menu and note that the values are filled in. Confirm that the Bus Voltage is correct. Enter the Encoder Feedback value for your encoder (see Table 5-1). Click “Download” when finished.

Table 5-1 Encoder Feedback

 

Encoder Feedback

 

 

Encoder Resolution

 

LMBLxx–A or

LMBLxx–E

LMCF (All)

micron

 

counts / meter

counts / mm

LMBLxx–B

 

 

 

 

 

 

 

not available

1143

762

20

 

50,000

50

1143

2286

1524

10

 

100,000

100

2286

4572

3048

5

 

200,000

200

5715

11430

7620

2

 

500,000

500

11430

14 bits maximum

15240

1

 

1,000,000

1,000

For encoders other than those listed in Table 5-1, calculate the encoder resolution as follows: (An example of a 5 micron encoder with an LMCF motor is given).

Encoder Feedback

+

motor pitch (mm)

+

60.96

+ 3048

 

 

 

 

 

 

 

1

 

1

 

 

 

 

 

￿

 

￿x4

￿

 

￿x4

 

 

 

 

(200)

 

 

￿counts per mm￿

Where:

motor pitch = 45.72 mm (LMBLxx–A or B series) motor pitch = 91.44 mm (LMBLxx–E series) motor pitch = 60.96 mm (LMCF cog free motors)

MN1851

Operation 5-7

Page 42
Image 42
Baldor MN1851 manual Encoder Feedback Motor pitch mm 60.96, Lmcf All Micron Counts / meter Counts / mm