X1 Possible Faults – Continued

X1 Fault

Display

Description

12

“FAULT_RELAY”

when fault relay is closed. Displays ’9’.

13

“EAF”

N.I

14

“MISSING INT”

N.I

 

 

 

15

“POWER_ID”

DRV.ID != SYS.POWER. Displays small ’u’.

16

“CW_CCW”

Both limit switches are on. Displays ’L’.

17

“DESIGN_FAILURE”

Control design fail. Displays small ’c’.

18

“EE_CLEARED”

EEPROM header stamp was not detected.

 

 

Displays big ’U’

 

 

 

19

“EE_INTEGRITY”

EEPROM footer stamp was not detected. Displays big ’A’.

 

 

 

20

“EAF Drive Temp”

EAF drive over temperature error. Displays ’6’.

 

 

 

21

“EAF Motor Temp”

EAF motor over temperature error. Displays ’6’.

22

“EAF Drive I2T”

EAF drive I2T error. Displays ’6’.

23

“EAF Motor I2T”

EAF motor I2T error. Displays ’6’.

Methods:

Command

Description

Parameter

Units

Range

FRST

Resets system faults if allowed. Reset is not allowed, if

 

error is still pending.

 

 

 

 

 

 

 

 

LOGRST

Resets system fault log

Communication Settings

Parameter:

Command

Description

Units

Range

Default

E2 / Par. set

ECHO

Disable / enable echoing for input

“ON/OFF

“ON”

– /

 

characters

 

 

 

 

 

 

 

 

 

 

PROMPT

Enables / disables terminal prompt

“ON/OFF

“ON”

– /

 

 

 

 

 

 

TALK

Enables / Disables terminal error

“ON/OFF

“ON”

– /

 

notification

 

 

 

 

Variable:

Command

Description

Units

Range

Default

E2 / Par. set

COM.STTS

Queries the most recent communication

0:65535

 

– /

 

handler error

 

 

 

 

Methods:

Command

Description

Parameter

Units

Range

B

Opens communication to the drive, called by its address

Address

0 : 7

 

(the addresses a constant, which can be queried by

 

 

 

 

COM.ADDR or SYS.STTS)

 

 

 

 

 

 

 

 