Bay Technical Associates none manual Electrical Specifications, Environmental Specifications

Models: none

1 156
Download 156 pages 62.12 Kb
Page 122
Image 122

Installing and Operating BayStack ARN Routers

If you are installing your ARN in an electronic enclosure rack, make sure that the rack meets the following specifications:

Heavy-duty steel construction

Electronic Industries Association (EIA) standard hole-spacing

Width of 19 in. (48.26 cm)

Depth of 24 in. (60.96 cm)

Electrical Specifications

Your installation site must meet the following power requirements:

Proximity to wall receptacle: within 6 ft (1.8 m) of the ARN

Voltage: 100 to 240 Vac

Amperage: 0.5 to 1.0 A

Table C-1 lists the wall outlet requirements.

Table C-1.

ARN Wall Outlet Requirements

 

 

 

 

 

Country

 

Outlet

Voltage

 

 

 

 

United States/

 

National Electrical Manufacturers

100 to 120 V

Canada

 

Association (NEMA) 5-15P standard outlet

 

 

 

 

Any other country

Your ARN distributor informs you of the

200 to 240 V

 

 

outlet you need.

 

 

 

 

 

Environmental Specifications

The environmental requirements of the ARN are as follows:

Altitude: 0 to 8,000 ft (0 to 2,438.4 m)

Humidity: 10% to 90%, noncondensing

Temperature: 32°F to 104°F (0°C to 40°C) stable

C-2

114200 Rev. A

Page 122
Image 122