Operating the ARN

Resetting the ARN

The Reset button is set inside the ARN back panel and resides next to the Flash card slot, as shown in Figure 3-3.

UL

Redundant Power

100-240~

U

1.2A

L

50-60Hz

 

Console

Modem

Reset button

ARN0052A

Figure 3-3. ARN Reset Button

To press the Reset button, insert a small pointed object (for example, a paper clip) into the Reset button hole.

You can use the Reset button to reboot the ARN hardware without cycling power, as follows:

To warm-bootthe ARN (no diagnostic tests run), press the Reset button for less than 5 seconds.

To cold-bootthe ARN (diagnostic tests run), press the Reset button for more than 5 seconds.

Note: If you reset the ARN while it is running its diagnostic tests, the LEDs remain in the state they were in when you pressed the Reset button. You must cycle power on the ARN to reset the LEDs.