Operating the ARN

Table 3-1 describes the base module diagnostic LEDs.

Table 3-1.

Base Module Diagnostic LEDs

 

 

 

LED

 

Meaning

 

 

 

Run

 

Flashes for 1 to 3 minutes, indicating that diagnostic tests are

 

 

running. When it lights again and remains on, the ARN is

 

 

operational.

 

 

 

Boot

 

Lights for 1 to 3 minutes, indicating that diagnostic tests were

 

 

successful and the ARN is booting.

 

 

 

Fail

 

Lights again and remains on when diagnostic failure occurs.

 

 

 

Pwr

 

Lights and remains on when the ARN is on and receiving

 

 

power.

 

 

 

RPS

 

Lights and remains on when the redundant power supply

 

 

(optional) is operating.

 

 

 

Fan

 

Lights and remains on when the ARN cooling fan is operating.

 

 

 

Base

 

Lights and remains on when the base module is operating

 

 

properly. Flashes slowly to indicate that the module is running

 

 

its diagnostic tests. Flashes rapidly to indicate that the module

 

 

failed its diagnostic tests.

 

 

 

Adapter1

 

Lights and remains on when adapter module #1 is operating

 

 

properly. Flashes slowly to indicate that the module is running

 

 

its diagnostic tests. Flashes rapidly to indicate that the module

 

 

failed its diagnostic tests.

 

 

 

Adapter2

 

Lights and remains on when adapter module #2 is operating

 

 

properly. Flashes slowly to indicate that the module is running

 

 

its diagnostic tests. Flashes rapidly to indicate that the module

 

 

failed its diagnostic tests.

 

 

 

Expansion

 

Lights and remains on when an expansion module is installed

 

 

and operating properly. Flashes slowly to indicate that the

 

 

module is running its diagnostic tests. Flashes rapidly to

 

 

indicate that the module failed its diagnostic tests.

 

 

 

DCM

 

Lights and remains on when an RMON DCM is installed and

 

 

operating properly. Flashes slowly to indicate that the module

 

 

is running its diagnostic tests. Flashes rapidly to indicate that

 

 

the module failed its diagnostic tests.

 

 

 

PCMCIA

 

Lights and remains on when the ARN contains a flash

 

 

memory card in its PCMCIA slot.

 

 

 

114200 Rev. A

3-3

Page 81
Image 81
Bay Technical Associates none manual Base Module Diagnostic LEDs, Meaning