Installing the BayStack Advanced Remote Node
Connecting to a V.34 Modem Interface
You can connect an
Note: The default settings for the
Table
Table | V.34 Modem Adapter Module Defaults | |
|
| |
Modem Signal/Parameter | Value | |
|
| |
Clear To Send (CTS) | On | |
|
| |
Data Terminal Ready (DTR) | Depends on the modem type. Set the modem to | |
|
| answer incoming calls when DTR is active. |
|
| |
Data Carrier Detect (DCD) or RLSD | On while carrier is present (the ARN uses DCD to | |
|
| detect modem connect and disconnect). |
|
| |
Data Set Ready (DSR) | On | |
|
| |
Ready to Send (RTS) | Ignore | |
|
| |
Synchronous/Asynchronous Mode | Asynchronous | |
|
|
|
AutoAnswer |
| Set on n rings with DTR active (n must be greater |
|
| than 0). |
|
| |
Local Character Echo | Off | |
|
| |
Supervisory Functions | Off | |
|
|
|
Baud Rate |
| 28800 |
|
|
|
Data Bits |
| 8 |
|
|
|
Stop Bits |
| 1 |
|
|
|
Parity |
| None |
|
|
|