7-4

System-related Log Message

S004 Starting up the system (info)
Message Starting WebView
Explanation Starting up WebView Livescope.
Log Messages
The Syslog log messages are classified into the following 3 categories. Classification details are
dealt with in the UNIX syslog.
Classification Level Fault Severity
err Error Fault involving a malfunction (operation interrupted)
warning Warning Fault not involving malfunction
info Information Information on correct operation

Application-related Log Messages

A007 View restriction setting error (warning)
Message inconsistent view restriction for camera [1]
Explanation The view restrictions settings are corrupted. The camera control functions cannot be used.
Response Restore the factory default settings or reset the permitted field of view restrictions.
A008 Compatibility error in the view restrictions settings (warning)
Message unacceptable view restriction for camera [1]
Explanation Even in the telephoto field of view, the view restriction settings cannot be satisfied in the
horizontal or vertical direction. When this occurs, the zoom setting is fixed at the telephoto
field of view, and camera head control is prohibited in directions that do not satisfy the
permitted field of view restrictions.
Response Set appropriate values for the permitted field of view restrictions.
A011 Camera control error (warning)
Message VB-C10 (VB-C10R) [1] malfunction (%1)
%1 Error (read|write|timeout|...)
Explanation Camera control I/O error.
Response If this occurs frequently, this is a malfunction. Contact an authorized Canon service
representative.
A022 Applet archive load failure (warning)
Message archive/%1 not found
%1 Applet archive name (glimpse.cab|glimpse.zip|lvapplet.cab|lvapplet.zip|imagemap. gif)
Explanation The applet archive file does not exist or is corrupted.
Response Copy the missing (or damaged) file in the “/archive” directory from the CD-ROM and reboot.
The original applet archive file is in the CD-ROM.