Detail Settings
Schedule
“Record pictures according to a schedule”
When this is selected, pictures are recorded at the interval set below. The interval can be set for every 1 to 59 seconds, every 1 to 59 minutes, or every 1 to 24 hours.
“Camera Position”
Select the angle to be used when recording pictures. Select “Not Specified” or from Preset 1 to 8 (→ P.3- 15).
“Camera Stabilization Time”
The time set here is the time allowed for camera operation to stabilize before it starts recording pictures. Maximum setting is 10 seconds, enter an integer between 0 and 10.
External Device Names
Set names for the external input/output devices used in
WebView Livescope MV.
Be sure to enter the device name.
* “External Device Input” and “Schedule” cannot be used together.
● The maximum memory capacity that can be used for recording pictures is
Setup Procedures
Note
approximately 5 MB. Available space can be checked with the Administration Tools settings page (→
●Recorded pictures are deleted when power to the
or the
●Recorded pictures are not overwritten. Once the recording picture memory
(approximately 5 MB) becomes full, recording stops. Use the Administration Tools Settings Page (→
Click the “OK” button to change the settings. To discard the changes, click the “Cancel” button. This returns you to the settings title page.
Tip
The amount of data for a still picture varies depending on the settings for video capture size and video quality (→
KB is the standard when the video capture size is set to 320 ⋅ 240 and the video quality is set to 3 (In some cases this may be exceeded). To check the amount of data for a still picture, select “View” - “Video information” from the menu after you start up the Helper Viewer, then check the “Size” value.