Before Using the VB-C10/VB-C10R

Installing the VB-C10/VB-C10R

VB-C10 Installation

Install in a flat and stable location.

VB-C10R Installation

Firmly tighten the 2 screws (not supplied).

Mounting plate

VB-C10R

Screw

Screw

(Installation)

Distance between tapped holes: 120 mm (4 18/25 in.)

Tapped hole diameter: 6.0 mm (1/4 in.)

Mounting plate thickness: 1.6 mm (1/16 in.)

aWARNING:

Install the camera securely.

When installing the VB-C10R on the ceiling, contact your Canon dealer.

When installing the VB-C10R on the ceiling, check that the ceiling is strong enough to bear the weight of the VB-C10R including the mounting plate. Installation in a weak location could result in the VB-C10R falling and causing serious injury.

At least once a year, check for looseness in the camera installation mount. (If the optional wide-angle converter is used, check the converter mount also.)

The permissible camera installation angles are ±20° from the horizontal. (±15°

Note

when the optional wide-angle converter is used for the VB-C10.)

The MAC address required when making network settings is shown on the bottom of the VB-C10/VB-C10R (P.1-11). Please make a note of it before installing this unit (P. 3-3).

Using a Tripod (VB-C10)

The screw for mounting a tripod is on the bottom of the VB-C10 toward the front.

Do not overtighten the mounting screw.

30 mm

(1 3/ in.)

Less than

Note

If excessive force is used to tighten the mounting screw, camera head movement may be impeded, or other malfunctions may result.

16

or wider

6.0 mm (1/4 in.)

Mounting screw

Always use a tripod mounting screw that is less than 6.0 mm (1/4 in.) in length. The use of screws 6.0 mm (1/4 in.) long or longer could damage the camera. Also, the tripod seat used should be at least 30 mm (1 3/16 in.) in diameter.