Detail Settings
WebView Livescope Setting Settings Page
Make the various settings such as the number of simultaneous clients, frame rate, and maximum
camera control time.
“Restrict Service Time”
When you want to set a time for videos to be distributed to the WebView Livescope Viewer, select this option, and specify the Start and Stop times.
With Admin Viewer, connections can also be made and videos viewed at times other than those set (→
WebView Livescope
“Video Transmission Port”
Set a TCP port number to be used for transmitting videos between the
“Camera Control Port”
Set a TCP port number to be used for controlling the camera between the
“Maximum Number of Clients”
Sets the maximum number of clients that can simultaneously be connected using the WebView Livescope Viewer. Enter an integer between 1 and 20.
“Control Queue Length”
Sets the length of the queue when multiple clients are waiting for control privilege under the WebView Livescope Viewer. Enter an integer between 0 and 20. The maximum number is 20. When set to “0”, only the Admin Viewer is permitted to control the camera.
“Maximum Frame Rate (fps)”
Sets the maximum number of frames captured per second. Enter a number between 0.1 and 30. The maximum frame rate is 30 fps.
“Maximum View Time (sec)”
Sets the maximum time the clients can view videos using the WebView Livescope Viewer. Enter an integer between 0 and 65535. A setting of 0 disables the time limitation (unlimited connection time).
“Maximum Camera Control Time (sec)”
Sets the maximum time one client can keep the camera control privilege using the WebView Livescope Viewer. Enter an integer between 1 and 3600. The maximum control time is 3600 seconds.
“Camera Stabilization Time (msec.)”
When the GetStillImage command (→
Click the “OK” button to change the settings. To discard the changes, click the “Cancel”
button. This returns you to the settings title page.