Log Messages

A008 Compatibility error in the view restrictions settings (warning)

Message

unacceptable view restriction for camera[1]

 

 

Explanation

Even in the telephoto field of view, the view restriction settings cannot be

 

satisfied in the horizontal or vertical direction. When this occurs, the zoom

 

setting is fixed at the telephoto field of view, and camera head control is

 

prohibited in directions that do not satisfy the permitted field of view restrictions.

 

 

Response

Set appropriate values for the view restrictions.

 

 

A010 Camera control driver start and stop (info)

Message

%1 driver for camera[1] %2

 

 

%1

Camera type (Canon VB-C50Fi)

 

 

%2

started stopped

 

 

Explanation

The camera control device was detected and the driver started up, or a

 

camera control device error was detected and the driver stopped.

 

 

A011 Camera control device error (warning)

Message

%1[1] malfunction (%2)

 

 

%1

Camera type (Canon VB-C50Fi)

 

 

%2

Error (read write timeout ...)

 

 

Explanation

Camera control device I/O error.

 

 

Response

There is a malfunction if it occurs repeatedly. Contact an authorized Canon

 

service representative.

 

 

A012 WebView Livescope client start and stop (info)

Message

%1@%2 %3

 

 

%1

Client type (LS/D LS/H)

 

 

%2

Client host IP address

 

 

%3

connected closed

 

 

Explanation

Connection and disconnection of TCP version WebView client (LS/D) and

 

HTTP version WebView client (LS/H) excluding still images.

 

 

A014 Access prohibited due to host restriction (notice)

Message

LS@%1 access denied

 

 

%1

Client host IP address

 

 

Explanation

Access from the client was denied due to host restrictions.

 

 