Specifications
External Device I/O Terminals
You can use Input/Output external devices together with the
External Device Input Terminals (IN+, IN–)
The external device input terminals consist of 2 terminals (IN+,
Connect any sensors and switches to terminals with electrically separate GND terminals and power supplies.
External Device Output Terminals (OUT A, OUT B, OUT C)
The external device output terminals consist of 3 terminals (OUT A, OUT B, OUT C). There is no distinction between “+” and
*External input status can be checked and external output status can be controlled using Admin Viewer (→
Loads connected to the output terminals should be within the following ratings:
Rating across the output terminals: Up to 50 V DC
Continuous load current: 100 mA
Internal Connection Chart
|
| +3.3V | |
10kΩ | 10kΩ | 10kΩ | |
+ | |||
|
| ||
Internal | 0.1∝F | Input terminals | |
IN+, IN– | |||
| – | ||
controller |
|
| |
|
| Output terminals | |
|
| OUT A, OUT B |
You need the
Tip device.
Appendix