Chapter 5: FN10 Filters

18.Enter the field value.

19.Enter the field mask.

20.Select the operator.

Or is the default. You do not need to enter anything if the filter will use the Or operator. If you want the filter to use the And operator, type And.

21.Enter the filter number.

One (1) is the default. You do not need to enter anything if the filter number is 1.

If you want the filter to have an index number other than 1, enter the value you want to use.

LCM displays the filter you entered and prompts you to save it. Enter y (Yes) to save the filter, or n (No) to cancel it. If you save the filter, it is redisplayed.

5.5.1 Modifying a Port Filter

You modify a Port filter in much the same way as you add one. LCM prompts you through each field. To modify a Port filter, begin with the steps below, then follow the prompts as if you were adding a filter.

At the LCM prompt:

1.Type filters modify

LCM prompts you for the filter index (number).

2.Enter the filter index number.

LCM displays the filter type field and prompts you through the filter fields in the same way as when you add a filter. What you had previously entered becomes the default value and is displayed in brackets [ ]. Make any changes you want following the instructions for adding a filter.

Page 5-22

Fast Network 10 User Guide

Page 102
Image 102
Enterasys Networks Fast Network 10 manual Modifying a Port Filter