Chapter 9 Operational Settings
■Resetting the counters
When you have replaced the consumables, reset the corresponding counters in the following procedure.
1 Click the [Clear] button for the consumable(s) that you replaced.
DThe counter is reset to 0.
2 Click the [OK] button in the Software Operation Panel.
■Message for replacing the consumable
The following message may appear while using the scanner.
Message
Check the message and replace the consumable accordingly.
If you click the [Ignore] button, the message disappears and the scan can be continued. However, it is recommended that you replace the consumable as soon as possible.
To stop the scan and replace the consumable right away, click the [Cancel] button.
For details about replacing consumables, refer to the following:
zPad assy
"7.2 Replacing the Pad Assy" (page 93)
zPick roller
DA confirmation message appears.
3 Click the [OK] button.
DThe settings are saved.
138