Chapter 6 Daily Care

6.1 Cleaning Materials and Locations that Require Cleaning

Cleaning Materials

Product Name

Part No.

Notes

Cleaner F1

PA03950-

100 ml

 

0352

Moisten a cloth with this liquid to

 

 

wipe the scanner clean.

 

 

It may take a long time if an

 

 

excessive amount is used. Moisten

 

 

the cloth with moderate quantity.

 

 

Wipe off the cleaner completely to

 

 

leave no residue on the cleaned

 

 

parts.

Cleaning Paper

CA99501-

Use this paper with Cleaner F1.

 

0012

 

Cleaning Wipe

PA03950-

24 packets

 

0419

Pre-moistened with Cleaner F1. It

 

 

can be used instead of moistening a

 

 

cloth with Cleaner F1.

Dry cloth

Commercially available

For more information about the cleaning materials, contact the FUJITSU scanner dealer where you purchased the scanner or an authorized FUJITSU scanner service provider.

Location and Frequency

LocationFrequency

Pad Assy

Every 1,000 sheets

Ultrasonic Sensor

Idler Roller

Glass

Pick Roller

Feed Roller

Eject Roller

Cleaning cycles may vary depending on the condition of the

documents. Also, cleaning must be performed more frequently when the following types of documents are scanned:

z Smooth-faced documents such as coated paper

z Documents with printed text/graphics that almost cover the

entire surface

z Chemically-treated documents such as carbonless paper z Documents containing a large amount of calcium carbonate z Documents written with lead pencil

z Documents on which the toner is not sufficiently fused

86