Chapter 9 Operational Settings

Range

Description

 

 

End

Displays the end position of the detection

(Middle)

by the length from the leading edge of the

 

document.

 

Range: 0 to 510 mm, in 2 mm increments,

 

Start<End

 

 

zWhen both [Start] and [End] are set to "0", multifeed detection is performed for the whole area regardless of whether it is enabled or disabled.

zTo disable multifeed detection for the whole document, select [Disable] and set the start position to "0" and the end position to equal the document length or longer.

zIf you set a value larger than the document length for the start position, selecting [Disable] detects the whole length of the document and selecting [Enable] disables the multifeed detection.

zIn order to detect multifeeds, the detection range must be at least 5 mm long.

Configure the setting so that the value of the end position minus the start position is 6 mm or more.

zYou can also set the start and the end positions by the following methods:

-Draw an area with the mouse on the displayed image.

-Drag the handles for [Start] and [End] positions on the displayed image.

Example 1:

Position: Middle

Selected range = Enable, Start = 50 mm, End = 200 mm

direction

50

50

 

Feed

200

 

Unit: mm

Multifeeds are detected for the area in light blue.

148