Chapter 9 Operational Settings
Range | Description |
|
|
End | Displays the end position of the detection |
(Middle) | by the length from the leading edge of the |
| document. |
| Range: 0 to 510 mm, in 2 mm increments, |
| Start<End |
|
|
zWhen both [Start] and [End] are set to "0", multifeed detection is performed for the whole area regardless of whether it is enabled or disabled.
zTo disable multifeed detection for the whole document, select [Disable] and set the start position to "0" and the end position to equal the document length or longer.
zIf you set a value larger than the document length for the start position, selecting [Disable] detects the whole length of the document and selecting [Enable] disables the multifeed detection.
zIn order to detect multifeeds, the detection range must be at least 5 mm long.
Configure the setting so that the value of the end position minus the start position is 6 mm or more.
zYou can also set the start and the end positions by the following methods:
-Draw an area with the mouse on the displayed image.
-Drag the handles for [Start] and [End] positions on the displayed image.
Example 1:
Position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
direction | 50 | |
50 | ||
| ||
Feed | 200 | |
|
Unit: mm
Multifeeds are detected for the area in light blue.
148