GE C11, AF-300 manual E Extension Terminal Functions, C Control Functions of Frequency

Models: C11 AF-300

1 98
Download 98 pages 7.53 Kb
Page 37
Image 37
E: Extension Terminal Functions

Change during operation: N = impossible, Y* = possible (enabled by using

FUNC DATA

), Y= possible (enabled by using C: Control Functions of FrequencyManual backgroundManual backgroundManual backgroundManual backgroundManual background )

E: Extension Terminal Functions

Func-

 

 

 

 

 

Change

 

tion

 

 

 

Min.

Factory

User

Name

Setting range

Unit

during

code

unit

setting

setting

 

 

 

operation

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

E01

X1 terminal function

Use the code values listed below to se-

-

-

0

N

 

 

X2 terminal function

lect [X1], [X2] and [X3] terminal func-

 

 

 

 

 

E02

-

-

2

N

 

 

X3 terminal function

tions.

 

 

 

 

 

E03

-

-

3

N

 

 

 

0: Multistep frequency 1 (SS1)

 

 

 

 

 

 

 

1: Multistep frequency 2 (SS2)

 

 

 

 

 

 

 

2: Coast-to-stop command (BX)

 

 

 

 

 

 

 

3: Alarm reset (RST)

 

 

 

 

 

 

 

4: External alarm (THR)

 

 

 

 

 

 

 

5: Write enable command for keypad

 

 

 

 

 

 

 

(WE-KP)

 

 

 

 

 

 

 

6: PID control cancel (Hz/PID)

 

 

 

 

 

 

 

7: Link operation selection (LE)

 

 

 

 

 

 

 

 

 

 

 

 

 

C: Control Functions of Frequency

Func-

 

 

 

 

Factory

Change

 

tion

Name

Setting range

 

Min.

User

Unit

during

code

unit

setting

setting

 

 

 

operation

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

C01

Jump frequency 1

0 to 120Hz

Hz

1

0

Y

 

C02

2

 

 

1

0

Y

 

C03

3

 

 

1

0

Y

 

C04

(Hysteresis)

0 to 30Hz

Hz

1

3

Y

 

C05

Multistep frequency 1

0.0 to 120Hz

Hz

0.1

0.0

Y

 

C06

2

 

 

0.1

0.0

Y

 

 

 

 

 

 

 

 

 

C07

3

 

 

0.1

0.0

Y

 

-35-

Page 37
Image 37
GE C11, AF-300 manual E Extension Terminal Functions, C Control Functions of Frequency