Item

 

Specifications

Remarks

 

Installation

Indoor use only. Do not install a dusty location(Degree of pollution: 2) or

 

 

location

expose to direct sunlight, corrosive gases, flammable gases.

 

 

Ambient

-10 to +50°C (+14 to +122°F )

 

 

temperature

 

 

 

 

Ambient

5 to 95%RH ( No condensation )

 

Environment

humidity

 

 

 

Altitude

3300 Feet (1000 m) or less

 

 

 

 

 

Vibration

3 mm:

2 to less than 9 Hz

 

 

9.8m/s2:

9 to less than 20 Hz

 

 

2m/s2:

20 to less than 55 Hz

 

 

 

 

 

 

1m/s2:

55 to less than 200 Hz

 

 

Storage tem-

-25 to +65°C

 

 

perature

 

 

 

 

Storage humid-

5 to 95% RH (No condensation)

 

 

ity

 

 

 

 

Higher

Terminal for connecting power-factor correcting DC reactor (DCR) is pro-

P1, P(+) terminal

 

harmonics

vided as standard.

 

 

current

 

 

 

Others

suppression

 

 

 

Charging sup-

Charging suppression resistor is built-in for all drive unit.

 

pression resis-

 

 

 

 

tor

 

 

 

 

Cooling fan

Cooling fan can be automatically stopped when drive is stopped.

 

 

ON/OFF con-

 

 

 

 

trol

 

 

 

- 83-

Page 85
Image 85
GE C11, AF-300 manual