Change during operation: N = impossible, Y* = possible (enabled by using FUNCDATA
), Y= possible (enabled by using )
F27 Motor sound (sound tone)
Factory | Change during |
setting | operation |
0 | Y |
This function adjusts the motor operation sound when a value of 7 or less is set with function F26.
0
to
3
Level 0
Level 3
F30 | FM terminal (voltage adjust) |
|
Factory | Change during |
setting | operation |
| |
100% | Y |
This function regulates the frequency meter voltage level output to the FM terminal in the range from 0 to 200% (in 1% step).
0 (Full scale about 0Vdc)
to
2 0 0
(Full scale about 11Vdc)
| 11V | 200% |
| Note : Output to the FM terminal is pulse output |
|
|
|
| |
Output | 10V |
| 100% | with constant frequency and variable duty. |
voltage |
|
|
| Variable |
| 5V |
| 50% | Approx. 13V |
|
|
|
| |
|
| 50% | 100% |
|
Output/full scale
F31 FM terminal (Function)
Fixed to 121.6Hz
Factory | Change during |
setting | operation |
| |
0 | Y* |
This function selects the contents of output to the FM terminal.
0 Output frequency (maximum output frequency = 100%)
1 Output current (drive rated current x 2 = 100%)
2 PID feedback value (full scale = 100%) 3 DC link circuit voltage (500Vdc = 100%)