GE C11, AF-300 When motor stalls during acceleration, When motor generates abnormal heat, to 0?

Models: C11 AF-300

1 98
Download 98 pages 7.53 Kb
Page 71
Image 71
(3) When motor stalls during acceleration

(3) When motor stalls during acceleration

Motor stalls during accel- eration

Acceleration time setting too short?

No

Moment of inertia of motor or load excessive?

No

Motor terminal voltage lowered?

No

Torque of load excessive?

Yes

Yes

Yes

Yes

No

Prolong time setting.

 

 

 

 

 

 

 

 

 

 

Special motor in use?

Yes

Consult with GE Fuji..

 

 

 

 

 

 

 

 

No

 

 

 

Reduce moment of inertia

 

 

 

 

 

 

Use thicker cable for wir-

 

of load or increase drive

ing between drive and mo-

 

capacity.

tor, or shorten wiring

 

 

length.

 

 

 

 

 

 

 

 

Reduce torque of load or increase drive capacity.

Setting of torque boost amount correct?

Yes

Probable faulty drive or error because of noise, etc. Contact GE Fuji.

Increase torque boost

No

(4) When motor generates abnormal heat amount.

(4) When motor generates abnormal heat

(5) When function change disabled

Motor generates ab-

Function change is disabled.

normal heat

Any of E01, E02, E03 set

YES

to 5?

 

Short-circuit between ter- minals X1,X2,X3 corre- sponding to function set to 5 and CM terminal.

V/f pattern fitted to mo- tor?

Yes

Motor been contin uously operated at extremely low speed?

No

Yes

Change the setting.

Use motor exclusive to drive.

 

NO

 

 

 

 

 

 

 

 

 

NO

 

 

F00 set

to 0?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

Attempt made to

change

 

 

 

 

 

 

an unchangeable function

YES

during operation?

 

 

 

 

 

Set F00 to 0.

Change function after stopping drive.

No

Load excessive?

No

Is the output voltage (at terminals U,V,W) bal- anced?

No

Yes

Yes

Lighten load or increase motor capacity.

Faulty motor.

 

NO

 

 

 

Function to be changed

 

YES

F00 or H03?

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

Function to

be changed

 

 

 

F02? FWD or REV ter-

 

YES

 

 

 

minal connected to CM

 

 

 

 

 

terminal?

 

 

 

 

NO

 

 

 

Function to be changed F05,

 

YES

Press STOP key and UP or DOWN key simultaneously.

Open FWD and REV command.

Change other functions.

Probable faulty drive. Contact GE Fuji.

F06, F24, H01 or H02?

NO

Contact GE Fuji

-69-