GE AF-300 C03 Jump frequency 1, 2, C04 Jump frequency Hysteresis, C07 Multistep frequency setting

Models: C11 AF-300

1 98
Download 98 pages 7.53 Kb
Page 56
Image 56
C03 Jump frequency 1, 2, 3

Change during operation: N = impossible, Y* = possible (enabled by using

FUNC

 

DATA

C01

C02

C03 Jump frequency 1, 2, 3

), Y= possible (enabled by using

)

 

 

 

 

 

 

Factory

Change during

 

 

setting

operation

 

C01

0.0Hz

Y

 

C02

0.0Hz

Y

 

C03

0.0Hz

Y

These functions jump frequencies to prevent overlap be- tween the load mechanical resonance point and drive output frequency.

Up to three jump points can be set.

These function do not operate when 0Hz is set.

No frequency is jumped during acceleration and decel- eration.

If three continuous frequencies are set, the total of the three jump widths is set as the jump width.

Output Frequency

 

Jump

 

frequency

Jump width

Jump

 

frequency

Jump width

 

Jump

 

frequency

Jump width

 

Frequency setting

C04 Jump frequency (Hysteresis)

Factory

Change during

setting

operation

3Hz

Y

This function sets a jump width in a range from 0 to 30Hz in 1Hz step.

C05 Multistep frequency setting 1

C06 Multistep frequency setting 2

 

Factory

Change during

 

setting

operation

 

 

C05

0.0Hz

Y

C06

0.0Hz

Y

C07

0.0Hz

Y

C07 Multistep frequency setting 3

These functions set a multistep frequency setting from 0 to 120Hz in 0.1Hz step (for 99.9 Hz or less) or 1Hz step (for 100Hz or more) by switching the external contact signal.

The ON and OFF of terminal function SS1/SS2 (see explanation of E01, E02, and E03) switches between the frequencies set by these functions C05, C06, and C07.

P00 Motor characteristics

Factory

Change during

setting

operation

 

2

Y

This function removes abnormalities in the output current such as current vibration. 0 Current vibration is not suppressed.

to

C04 Jump frequency (Hysteresis)C05 Multistep frequency setting 1 1 C07 Multistep frequency setting 3P00 Motor characteristics 0 Current vibration is minimized.