6 Protective Function

6-1 List of protective functions

When the protective function is activated, drive output is instantly cut off (while the motor coasts until it is stopped), and an alarm is issued, and the details of the alarm are displayed on the keypad panel.

 

 

Table 6-1-1 List of Protective Functions

 

Keypad

 

 

 

Alarm Name

panel dis-

 

 

Contents of operation

 

play

 

 

 

Overcurrent

OC1

During acceleration

 

If the drive output current momentarily exceeds the over-

 

 

 

OC2

During deceleration

 

current detection level because of an overcurrent in the

 

 

 

 

OC3

While running at

 

motor or the short-circuit in the output circuit, the output is

 

constant speed

 

 

 

 

shut down, an alarm is issued, and the drive is tripped.

 

 

 

 

Overvoltage

 

During acceleration

 

If the DC voltage of the main circuit exceeds the overvolt-

OU1

 

age detection level because of an increase in the regenerat-

 

 

 

 

 

 

ing current from the motor, etc., output is shut down, an

 

OU2

During deceleration

 

alarm is issued, and the drive is tripped. However, protec-

 

 

tion against inadvertent overvoltage loading (e.g., high-

 

 

 

 

voltage line) might not be provided.

 

OU3

While running at

 

 

 

 

 

constant speed

 

 

 

 

 

 

Undervoltage

LU

If the DC voltage of the main circuit falls below the undervoltage detection level

 

 

because of a lowered power supply, output is shut down to protect the drive. If the

 

 

restart function after momentary power failure is not activated, an alarm is issued

 

 

and the drive is tripped.

 

 

 

If the restart function is activated, the drive restarts automatically with no alarm.

 

 

For further details of the protective function, refer to the descriptions of Function

 

 

F14.

 

Overheating of

OH1

If the temperature of the heat sink used for cooling the rectifier diodes and IGBTs

heat sink

 

rises because of cooling fan failure, etc., protective function is activated to stop

 

 

 

 

operation, an alarm is issued, and the drive is tripped.

External Alarm

OH2

If the control circuit terminal THR (functional change of X1 to X3 terminals) is

 

set to OFF, an alarm is issued and the drive is tripped.

 

 

 

OL

If the motor current exceeds the operating level set by the electronic thermal O/L

Motor overload

 

relay, output is shut down to protect the motor, an alarm is issued, and the drive is

 

 

 

 

tripped.

 

Drive overload

OLU

If the output current exceeds the drive rated overload current, output is shut down,

 

an alarm is issued, and the drive is tripped.

 

 