#1

#2

#3 & #4

Trigger Key Thumbwheel Setting

 

 

 

 

 

 

 

Class

Sub-class

Instance

Meaning

 

 

 

 

 

 

 

4

A

see valid

Thermal Demand Maximum

 

 

 

instances

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

4

B

see valid

Sliding Window Demand Maximum

 

 

 

instances

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

4

C

see valid

Hours - Net (Import - Export)

 

 

 

instances

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

4

D

see valid

Hours - Import

 

 

 

instances

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

4

E

see valid

Hours - Export

 

 

 

instances

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

4

F

see valid

Hours - Total (Import + Export)

 

 

 

instances

 

 

 

 

 

below

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instance

Measurement

 

Supported Modes

 

 

 

 

 

 

 

 

00

Volts LN Average

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

01

Volts LN Phase A

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

02

Volts LN Phase B

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

03

Volts LN Phase C

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

04

Volts LL Average

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

05

Volts LL Phase AB

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

06

Volts LL Phase BC

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

07

Volts LL Phase CA

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

08

Amps Average

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

09

Amps Phase A

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

0A

Amps Phase B

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

0B

Amps Phase C

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

0C

Amps Neutral

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

0D

Reserved

 

 

 

 

 

 

 

 

 

 

0E

Volts Imbalance (0-100)

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

0F

Amps Imbalance (0-100)

 

STD TD SD PD

 

 

 

 

 

 

 

 

10

kW Total

 

HS STD TD SD PD HRS

 

 

 

 

 

 

 

 

11

kW Phase A

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

12

kW Phase B

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

13

kW Phase C

 

HS STD TD SD PD

 

 

 

 

 

 

 

 

14

kVAR Total

 

STD TD SD PD HRS

 

 

 

 

 

 

 

 

15

kVAR Phase A

 

STD TD SD PD

 

 

 

 

 

 

 

 

16

kVAR Phase B

 

STD TD SD PD

 

 

 

 

 

 

 

 

17

kVAR Phase C

 

STD TD SD PD

 

 

 

 

 

 