WJ200 Series Inverter Quick Reference Guide
Page
Marking Requirements
UL→ Cautions, Warnings and Instructions
Terminal symbols and Screw size
Fuse Sizes
Inverter Specification Label
5AT 123 45A-001 1005
WJ200 Inverter Specifications
Model-specific tables for 200V and 400V class inverters
WJ200 Inverter Specifications, …
WJ200 inverters, 400V models
Derating
GFI
Basic System Description
Inverter +
Motor Output
Determining Wire and Fuse Sizes
Allowable current
Wire the Inverter Input to a Supply
T1 V/T2 W/T3 L1 S/L2 T/L3 U/T1 V/T2 W/T3
RB PD/+1 P/+
Three-phase 200V 11kW Three-phase 400V 11, 15kW
Key and Indicator Legend
Using the Front Panel Keypad
Power LED Alarm LED
Keypad Navigation Map
Keys, Modes, and Parameters
PRG LED
Group d
Group F
Save
Group a
F001
Key
Connecting to PLCs and Other Devices
GND
Example Wiring Diagram
Motor
Control Logic Signal Specifications
Pulse
Train
Output Input
Wiring sample of control logic terminal sink logic
SP, SN
Wire size for control and relay terminals
Sink/source logic of intelligent input terminals
Recommended ferrule
Intelligent Terminal Listing
Intelligent Inputs
Intelligent Outputs
Sink logic connection
Using Intelligent Input Terminals
Source logic connection
WJ200
Sinking Inputs, Internal Supply
Sourcing Inputs, Internal Supply
Sinking Inputs, External Supply
Sourcing Inputs, External Supply
Inserting
OFF
Forward Run/Stop and Reverse Run/Stop Commands
Option Terminal Code Symbol Function Name State Description
Required settings
Multi-Speed Select ~Binary Operation
FW,RV
Two Stage Acceleration and Deceleration
2CH
Unattended Start Protection
Option Terminal Function Name State Description Code Symbol
USP
Reset Inverter
Using Intelligent Output Terminals
Run Signal
Code Symbol
Option Terminal Function Name
Settings
Frequency Arrival Signals
Required
FA2/FA4
FA3/FA5
Stop
Alarm Signal
Trip
During normal operation
AM H O OI L
Analog Input Operation
AM H O OI
Other Analog Input-related topics
Pulse Train Input Operation
SN 7 6 5 4 3 2 1 L PLC P24
Analog Output Operation
AM signal offset and gain are adjustable, as indicated below
Monitoring functions
D006
D007
D008
D009
D029
D030
D050
D060
Main Profile Parameters
Standard Functions
A015
A220
A241
A021 ~ A035
A242
A043
A243
A044
A058
A059
A061
A261
A072
A073
A074
A075
A092
A292
A093
A293
A131
A132
A141
A142
A156
A157
A161
A162
Fine Tuning Functions
B012
B212
B013
B213
B025
B026
B027
B028
B037
B038
B039
B040
B060
B061
B062
B063
B087
B088
B089
B090
B096
B097
B100
B101
B133
B134
B145
B150
Intelligent Terminal Functions
C028
C030
C031
C032
C047
C052
C053
C054
C076
C077
C078
C081
C102
C103
C104
C105
C147
C148
C149
C150
Anlg
FWD, REV
Pidc
DWN
SF1
SF2
SF3
SF4
255
Run Signal When the inverter is in Run Mode
LOG2
LOG1
LOG3
C039
MO1
MO2
MO3
Motor Constants Functions
PM Motor Constants Functions
H112
H113
H116
H117
Expansion Card Functions
P041
P044
P045
P046
P072
P073
P075
P077
Monitoring Trip Events, History, & Conditions
Trip History and Inverter Status
Error Codes
Error Name Causes Code
E37
Error Name Descriptions Code
Restoring Factory Default Settings
Other indication
CE-EMC Installation Guidelines
Important notes
Page
Page
Installation for WJ200 series example of SF models
Metal plate earth
Hitachi EMC Recommendations
Functional Safety Certification in Progress
Introduction
Stop Category defined in EN60204-1
How it works
Installation
Wiring example
OFF
G9SX
GS9A
NE1A