Func.

 

Name

 

Description

 

 

Code

 

 

 

 

 

 

 

 

 

Run

Mode

Edit

Initialdata Units

 

A072

PID proportional gain

Proportional gain has a range of

 

1.0

 

 

 

 

0.00 to 25.00

 

 

 

 

 

 

 

 

 

 

 

 

 

A073

PID integral time constant

Integral time constant has a

 

1.0

sec

 

 

 

 

range of 0.0 to 3600 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

A074

PID derivative time constant

Derivative time constant has a

 

0.00

sec

 

 

 

 

range of 0.0 to 100 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

A075

PV scale conversion

Process Variable (PV), scale

 

1.00

 

 

 

 

factor (multiplier), range of 0.01

 

 

 

 

 

 

 

to 99.99

 

 

 

 

 

A076

PV source

Selects source of Process

 

00

 

 

 

 

Variable (PV), option codes:

 

 

 

 

 

 

 

00[OI] terminal (current in)

 

 

 

 

 

 

 

01[O] terminal (voltage in)

 

 

 

 

 

 

 

02Modbus network

 

 

 

 

 

 

 

03Pulse train input

 

 

 

 

 

 

 

10Calculate function output

 

 

 

 

 

A077

Reverse PID action

Two option codes:

 

00

 

 

 

 

00PID input = SP-PV

 

 

 

 

 

 

 

01PID input = -(SP-PV)

 

 

 

 

 

A078

PID output limit

Sets the limit of PID output as

 

0.0

%

 

 

 

 

percent of full scale,

 

 

 

 

 

 

 

range is 0.0 to 100.0%

 

 

 

 

 

a079

PID feed forward selection

Selects source of feed forward

 

00

 

 

 

 

gain, option codes:

 

 

 

 

 

 

 

00Disabled

 

 

 

 

 

 

 

01[O] terminal (voltage in)

 

 

 

 

 

 

 

02[OI] terminal (current in)

 

 

 

 

 

A081

AVR function select

Automatic (output) voltage

 

02

 

 

 

 

regulation, selects from three

 

 

 

 

 

 

AVR function select,

type of AVR functions, three

 

 

 

 

 

a281

option codes:

 

02

 

 

 

2nd motor

00AVR enabled

 

 

 

 

 

 

 

01AVR disabled

 

 

 

 

 

 

 

02AVR enabled except during

 

 

 

 

 

 

 

deceleration

 

 

 

 

 

A082

AVR voltage select

200V class inverter settings:

 

200/

V

 

 

 

 

……200/215/220/230/240

 

400

 

 

 

 

AVR voltage select,

400V class inverter settings:

 

 

V

 

 

a282

……380/400/415/440/460/480

 

200/

 

 

2nd motor

 

 

400

 

 

 

 

 

 

 

 

 

 

 

a083

AVR filter time constant

Define the time constant of the

 

0.300

sec

 

 

 

 

AVR filter, range is 0 to 10 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

a084

AVR deceleration gain

Gain adjustment of the braking

 

100.

%

 

 

 

 

performance, range is 50 to

 

 

 

 

 

 

 

200%

 

 

 

 

 

A085

Energy-saving operation mode

Two option codes:

 

00

 

 

 

 

00Normal operation

 

 

 

 

 

 

 

01Energy-saving operation

 

 

 

 

 

A086

Energy-saving mode tuning

Range is 0.0 to 100 %.

 

50.0

%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54