| Run |
|
|
|
|
Func. | Name |
| Description | Mode |
| Initialdata |
| Units |
Code |
|
|
| Edit |
|
|
|
|
B133 | Decel. overvolt. suppress |
| Proportional gain when b130=01. |
|
| 0.20 |
| − |
| proportional gain |
| Range is: 0.00 to 5.00 |
|
|
|
|
|
B134 | Decel. overvolt. suppress |
| Integration time when b130=01. |
|
| 1.0 |
| sec |
| integral time |
| Range is: 0.00 to 150.0 |
|
|
|
|
|
b145 | GS input mode |
| Two option codes: |
|
| 00 |
| - |
|
|
| 00…No trip (Hardware shutoff only) |
|
|
|
|
|
|
|
| 01…Trip |
|
|
|
|
|
b150 | Display ex.operator connected |
| When an external operator is |
|
| 001 |
| − |
|
|
| connected via |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| only one "d" parameter configured |
|
|
|
|
|
|
|
| in: |
|
|
|
|
|
|
|
| d001 ~ d030 |
|
|
|
|
|
b160 | 1st parameter of Dual Monitor |
| Set any two "d" parameters in b160 |
|
| 001 |
| − |
|
|
| and b161, then they can be |
|
|
|
|
|
|
|
| monitored in d050. The two |
|
|
|
|
|
|
|
| parameters are switched by |
|
|
|
|
|
|
|
| up/down keys. |
|
|
|
|
|
|
|
| Set range: d001 ~ d030 |
|
|
|
|
|
b161 | 2nd parameter of Dual Monitor |
|
|
|
| 002 |
| − |
|
|
|
|
|
|
|
|
|
b163 | Frequency set in monitoring |
| Two option codes: |
|
| 00 |
| - |
|
|
| 00…Freq. set disabled |
|
|
|
|
|
|
|
| 01…Freq. set enabled |
|
|
|
|
|
b164 | Automatic return to the initial |
| 10 min. after the last key operation, |
|
| 00 |
| - |
| display |
| display returns to the initial |
|
|
|
|
|
|
|
| parameter set by b038. Two option |
|
|
|
|
|
|
|
| codes: |
|
|
|
|
|
|
|
| 00…Disable |
|
|
|
|
|
|
|
| 01…Enable |
|
|
|
|
|
b165 | Ex. operator com. loss action |
| Five option codes: |
|
| 02 |
| - |
|
|
| 00…Trip |
|
|
|
|
|
|
|
| 01…Trip after deceleration to a stop |
|
|
|
|
|
|
|
| 02…Ignore |
|
|
|
|
|
|
|
| 03…Coasting (FRS) |
|
|
|
|
|
|
|
| 04…Decelerates to a stop |
|
|
|
|
|
b166 | Data Read/Write select |
| 00… Read/Write OK |
|
| 00 |
| - |
|
|
| 01… Protected |
|
|
|
|
|
b171 | Inverter mode selection |
| Three option codes: |
|
| 00 |
| - |
|
|
| 00…No function |
|
|
|
|
|
|
|
| 01…Std. IM (Induction Motor) |
|
|
|
|
|
|
|
| 03…PM (Permanent Magnet Motor) |
|
|
|
|
|
b180 | Initialization trigger |
| This is to perform initialization by |
|
| 00 |
| - |
| (*) |
| parameter input with b084, b085 and |
|
|
|
|
|
|
|
| b094. Two option codes: |
|
|
|
|
|
|
|
| 00…Initialization disable |
|
|
|
|
|
|
|
| 01…Perform initialization |
|
|
|
|
|
b190 | Password Settings A |
| 0000(Invalid Password) |
|
| 0000 |
| - |
|
|
|
|
|
|
|
| |
b191 | Password authentication A |
|
|
| 0000 |
| - | |
|
|
|
|
|
|
|
|
|
b192 | Password Settings B |
| 0000(Invalid Password) |
|
| 0000 |
| - |
|
|
|
|
|
|
|
| |
b193 | Password authentication B |
|
|
| 0000 |
| - | |
|
|
|
|
|
|
|
|
|
65