Expansion Card Functions

“P” parameters will be appeared when the expansion option is connected.

 

 

 

 

 

 

 

 

Run

 

 

 

 

 

 

 

 

Func.

Name

 

 

Description

 

 

Mode

 

 

Initial data

 

 

 

Units

 

Code

 

 

 

 

 

 

 

Edit

 

 

 

 

 

 

 

 

P001

Reaction when option card

 

 

Two option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

error occurs

 

 

00…Inverter trips

 

 

 

 

 

 

00

 

 

-

 

 

 

 

 

01…Ignores the error (Inverter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

continues operation)

 

 

 

 

 

 

 

 

 

 

 

P003

[EA] terminal selection

 

Three option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00…Speed reference (incl. PID)

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

01…For control with encoder

 

 

 

 

 

 

 

-

 

 

 

 

 

feedback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02…Extended terminal for EzSQ

 

 

 

 

 

 

 

 

 

 

 

P004

Pulse train input mode

 

 

Four option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

selection for feedback

 

 

00…Single-phase pulse [EA]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01…2-phase pulse (90° difference) 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

([EA] and [EB])

 

 

 

 

 

 

00

 

 

-

 

 

 

 

 

02…2-phase pulse (90° difference) 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

([EA] and [EB])

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03…Single-phase pulse [EA] and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

direction signal [EB]

 

 

 

 

 

 

 

 

 

 

 

P011

Encoder pulse setting

 

 

Sets the pulse number (ppr) of the

 

 

 

 

 

512.

 

 

-

 

 

 

 

 

encoder, set range is 32~1024

 

 

 

 

 

 

 

 

 

 

 

 

pulses

 

 

 

 

 

 

 

 

 

 

 

 

P012

Simple positioning selection

 

Two option codes:

 

 

 

 

 

 

00

 

 

-

 

 

 

 

 

00…simple positioning deactivated

 

 

 

 

 

 

 

 

 

 

 

 

01…simple positioning activated

 

 

 

 

 

 

 

 

 

 

 

p015

Creep Speed

 

 

Set range is start frequency (b082)

 

 

 

 

 

5.00

 

 

 

Hz

 

 

 

 

~10.00 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P026

Over-speed error detection

 

 

Set range is 0~150%

 

 

 

 

 

115.0

 

 

%

 

 

level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P027

Speed deviation error

 

 

Set range is 0~120 Hz

 

 

 

 

 

10.00

 

 

 

Hz

 

detection level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P031

Deceleration time Input Type

 

 

00…Operator, 01…EzSQ

 

 

 

 

 

00

 

 

-

 

P033

Torque command input

 

 

Three option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

selection

 

 

00…Analog voltage input [O]

 

 

 

 

 

00

 

 

-

 

 

 

 

 

01…Analog current input [OI]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

03…Operator, 06…Option

 

 

 

 

 

 

 

 

 

 

 

P034

Torque command level input

 

 

Set range is 0~200%

 

 

 

 

 

0.

 

 

%

 

p036

Torque bias mode selection

 

 

Two option codes:

 

 

 

 

 

 

00

 

 

-

 

 

 

 

 

00…No bias

01…Operator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

p037

Torque bias value setting

 

Range is –200~200%

 

 

 

 

 

0.

 

 

%

 

p038

Torque bias polar selection

 

 

Three option codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00…According to the sign

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

01…According to the rotation

 

 

 

 

 

 

 

-

 

 

 

 

 

direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05…Option

 

 

 

 

 

 

 

 

 

 

 

 

p039

Speed limit of Torque control

 

 

Set range is 0.00~120.00Hz

 

 

 

 

 

0.00

 

 

 

Hz

 

(Forward rotation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

p040

Speed limit of Torque control

 

 

Set range is 0.00~120.00Hz

 

 

 

 

 

0.00

 

 

 

Hz

 

(Forward rotation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

81

Page 83
Image 83
Hitachi hitachi series inverter user manual Expansion Card Functions