Run

 

 

Func.

 

Name

 

 

Description

 

Mode

Initial data

 

Code

 

 

 

 

 

 

Edit

 

 

H231

 

Motor constant R2,

 

 

 

 

 

 

 

 

 

2nd motor (Auto tuned data)

 

 

 

 

 

 

 

H032

 

Motor constant L

 

 

0.01~655.35mH

 

 

 

 

 

 

(Auto tuned data)

 

 

 

 

 

 

 

H232

 

Motor constant L,

 

 

 

 

 

 

 

 

 

2nd motor (Auto tuned data)

 

 

 

 

 

 

 

H033

 

Motor constant I0

 

 

0.01~655.35A

 

 

 

 

 

 

(Auto tuned data)

 

 

 

 

 

 

 

H233

 

Motor constant I0,

 

 

 

 

 

 

 

 

 

2nd motor (Auto tuned data)

 

 

 

 

 

 

 

H034

 

Motor constant J

 

 

0.001~9999 kgm2

 

 

 

 

 

 

(Auto tuned data)

 

 

 

 

 

 

 

H234

 

Motor constant J,

 

 

 

 

 

 

 

 

 

2nd motor (Auto tuned data)

 

 

 

 

 

 

 

H050

 

Slip compensation P gain

 

 

0.00-10.00

 

 

0.2

 

 

 

for V/f control with FB

 

 

 

 

 

 

 

H051

 

Slip compensation I gain

 

 

0.-1000.

 

 

2.

 

 

 

for V/f control with FB

 

 

 

 

 

 

 

Units

ohm

mH

mH

A

A

kgm2

kgm2

Times

(s)

PM Motor Constants Functions

 

 

 

 

 

 

 

Run

 

 

 

 

Func.

 

 

Name

 

 

Description

Mode

 

Initial data

 

Units

Code

 

 

 

 

 

 

Edit

 

 

 

 

 

 

 

 

 

 

00Hitachi standard

 

 

 

 

-

 

 

 

 

 

 

(Use H106-H110 at motor

 

 

 

 

 

H102

 

 

PM motor code setting

 

 

constants)

 

 

00

 

 

 

 

 

 

01Auto-Tuning

 

 

 

 

 

 

 

 

 

 

(Use H109-H110, H111-H113

 

 

 

 

 

 

 

 

 

 

 

at motor constants)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H103

 

 

PM motor capacity

 

 

0.1/0.2/0.4/0.55/0.75/1.1/1.5/2.2/

 

 

kW

 

kW

 

 

 

 

 

3.0/3.7/4.0/5.5/7.5/11.0/15.0/18.5

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H104

 

 

PM motor pole setting

 

 

2/4/6/8/10/12/14/16/18/20/22/24/26/

 

 

kW

 

Poles

 

 

 

 

28/30/32/34/36/38/40/42/44/46/48

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H105

 

 

PM Rated Current

 

 

(0.00-1.00)×Rated current of the

 

 

kW

 

A

 

 

 

 

inverter [A]

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H106

 

 

PM const R(Resistance)

 

 

0.001-65.535 [Ω]

 

 

kW

 

Ohm

 

 

 

 

 

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H107

 

 

PM const Ld

 

 

0.01-655.35 [mH]

 

 

kW

 

mH

 

 

(d-axis inductance)

 

 

 

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H108

 

 

PM const Lq

 

 

0.01-655.35 [mH]

 

 

kW

 

mH

 

 

(q-axis inductance)

 

 

 

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H109

 

 

PM const Ke

 

 

0.0001-6.5535 [V/(rad/s)]

 

 

kW

 

V/(rad/

 

 

(Induction voltage constant)

 

 

 

 

 

dependent

 

s)

 

 

 

 

 

 

 

 

 

 

 

 

H110

 

 

PM const J

 

 

0.001-9999.000 [kgm2]

 

 

kW

 

kgm^2

 

 

(Moment of inertia)

 

 

 

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H111

 

 

PM const R

 

 

0.001-65.535 [Ω]

 

 

kW

 

Ohm

 

 

(Resistance, Auto)

 

 

 

 

 

dependent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

79

Page 81
Image 81
Hitachi hitachi series inverter user manual PM Motor Constants Functions