[Setting example]

After power ON, changing from 0.00 display to change the A002 (Run command source) data.

Press [ESC] key to show the function code

ESC

d001

Data of d001 will be shown on the display after the first power ON

0.00

ESC

SET

Press [ESC] key to move on to the function group F001

F001

ESC

Press [ESC] key Once to move on to the function group A001.

A001

U V

Press Up key to change increase

function code (A001

A002)

Press SET key to display the data of A002

SET

Display is solid lighting.

A002

02

ESC

U

Press up key to increase the

V

data (02 01)

 

SET

01

Press SET key to set and save the data

When data is changed, the display starts blinking, which means that new data has not been activated yet.

SET :Fix and stores the data and moves back to the function code

ESC :Cancels the change and moves back to the function code

Function code dxxx are for monitor and not possible to change.

Function codes Fxxx other than F004 are reflected on the performance just after changing the data

(before pressing SET key), and there will be no blinking.