48
“d” Function
Func.
Code Name Description
Run
Mode
Edit
Units
d029 Positioning command monitor Displays the positioning command,
range is –268435455~+268435455
d030 Current position monitor Displays the current position, range
is –268435455~+268435455
d050 Dual monitor Displays two different data
configured in b160 and b161.
d060 Inverter mode monitor Displays currently selected inverter
mode :
I-C:IM CT mode/I-v:IM VT mode/
P:PM
D080 Trip counter Number of trip events,
Range is 0. to 65530
events
D081 Trip monitor 1
D082 Trip monitor 2
D083 Trip monitor 3
d084 Trip monitor 4
d085 Trip monitor 5
d086 Trip monitor 6
Displays trip event information:
Error code
Output frequency at trip point
Motor current at trip point
DC bus voltage at trip point
Cumulative inverter operation
time at trip point
Cumulative power-ON time at
trip point
d090 Warning monitor Displays the warning code
D102 DC bus voltage monitor Voltage of inverter internal DC bus,
Range is 0.0 to 999.9
V
d103 BRD load ratio monitor Usage ratio of integrated brake
chopper, range is 0.0~100.0%
%
D104 Electronic thermal monitor Accumulated value of electronic
thermal detection, range is from
0.0~100.0%
%