Run

 

 

Units

 

 

Func.

 

 

Name

 

 

 

 

 

Description

 

 

 

Mode

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

Edit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d029

 

Positioning command monitor

 

 

Displays

the

positioning

command,

 

 

 

 

 

 

 

 

 

 

 

range is –268435455~+268435455

 

 

 

 

 

 

d030

 

Current position monitor

 

 

Displays the current position, range

 

 

 

 

 

 

 

 

 

 

 

is –268435455~+268435455

 

 

 

 

 

 

 

d050

 

Dual monitor

 

 

Displays

two

different

data

 

 

 

 

 

 

 

 

 

 

 

configured in b160 and b161.

 

 

 

 

 

 

 

d060

 

Inverter mode monitor

 

 

 

Displays

currently

selected

inverter

 

 

 

 

 

 

 

 

 

 

 

mode :

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I-C:IM CT mode/I-v:IM VT mode/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P:PM

 

 

 

 

 

 

 

 

 

 

 

D080

 

Trip counter

 

 

 

Number of trip events,

 

 

 

 

 

events

 

 

 

 

 

 

 

 

Range is 0. to 65530

 

 

 

 

 

 

 

 

D081

 

Trip monitor 1

 

 

 

Displays trip event information:

 

 

 

 

 

 

 

 

 

 

 

Error code

 

 

 

 

 

 

 

 

 

D082

 

Trip monitor 2

 

 

 

 

 

 

 

 

 

 

 

 

 

Output frequency at trip point

 

 

 

 

 

 

 

 

 

 

 

Motor current at trip point

 

 

 

 

 

 

D083

 

Trip monitor 3

 

 

 

 

 

 

 

 

 

 

DC bus voltage at trip point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d084

 

Trip monitor 4

 

 

 

Cumulative inverter

operation

 

 

 

 

 

 

 

 

 

 

 

 

time at trip point

 

 

 

 

 

 

 

 

 

d085

 

Trip monitor 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cumulative power-ON time at

 

 

 

 

 

 

 

 

 

 

 

 

trip point

 

 

 

 

 

 

 

 

 

 

d086

 

Trip monitor 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

d090

 

Warning monitor

 

 

Displays the warning code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D102

 

DC bus voltage monitor

 

 

 

Voltage of inverter internal DC bus,

 

 

 

V

 

 

 

 

 

 

 

 

Range is 0.0 to 999.9

 

 

 

 

 

 

 

 

d103

 

BRD load ratio monitor

 

 

 

Usage ratio of integrated brake

 

 

%

 

 

 

 

 

 

 

 

 

chopper, range is 0.0~100.0%

 

 

 

 

 

 

D104

 

Electronic thermal monitor

 

 

Accumulated

value of

electronic

 

 

%

 

 

 

 

 

 

 

 

 

thermal detection, range is from

 

 

 

 

 

 

 

 

 

 

 

 

 

0.0~100.0%

 

 

 

 

 

 

 

 

 

 

48

Page 50
Image 50
Hitachi hitachi series inverter D029, D030, D050, D060, D080, D081, D082, D083, D084, D085, D086, D090, D102, D103, D104