Run

 

 

 

 

 

 

 

 

 

 

Func.

 

 

Name

 

 

Description

 

 

 

Mode

 

 

 

Initialdata

 

 

 

Units

 

 

Code

 

 

 

 

 

 

 

Edit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C147

 

Logic output 2 operator

 

 

Applies a logic function to calculate

 

 

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

[LOG] output state,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Three options:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00[LOG] = A AND B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01[LOG] = A OR B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02[LOG] = A XOR B

 

 

 

 

 

 

 

 

 

 

 

 

 

C148

 

Logic output 3 operand A

 

 

All the programmable functions

 

 

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

available for logic (discrete) outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

C149

 

Logic output 3 operand B

 

 

 

 

 

 

 

 

 

01

 

 

 

 

 

 

 

except LOG1 to LOG3, OPO, no

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C150

 

Logic output 3 operator

 

 

Applies a logic function to calculate

 

 

 

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

[LOG] output state,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Three options:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00[LOG] = A AND B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01[LOG] = A OR B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02[LOG] = A XOR B

 

 

 

 

 

 

 

 

 

 

 

 

 

C160

 

Input [1] response time

 

 

Sets response time of each input

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

terminal, set range:

 

 

 

 

 

 

 

 

 

 

 

 

 

C161

 

Input [2] response time

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

0 (x 2 [ms]) to 200 (x 2 [ms])

 

 

 

 

 

 

 

 

 

 

 

C162

 

Input [3] response time

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

(0 to 400 [ms])

 

 

 

 

 

 

 

 

 

 

 

C163

 

Input [4] response time

 

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

C164

 

Input [5] response time

 

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

C165

 

Input [6] response time

 

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

C166

 

Input [7] response time

 

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

C169

 

Multistage speed/position

 

 

Set range is 0. to 200. (x 10ms)

 

 

 

 

 

 

 

0.

 

 

 

ms

 

 

 

 

 

determination time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Function Summary Table – This table shows all thirty-one intelligent input functions at a glance. Detailed description of these functions, related parameters and settings, and example wiring diagrams are in “Using Intelligent Input Terminals” on page 27.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option

 

 

Terminal

 

 

Function Name

 

 

 

Description

 

 

Code

 

 

Symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

 

 

FW

FORWARD Run/Stop

 

ON

Inverter is in Run Mode, motor runs forward

 

 

 

 

OFF

Inverter is in Stop Mode, motor stops

 

 

 

 

 

 

 

 

 

 

 

 

01

 

 

RV

 

Reverse Run/Stop

 

ON

Inverter is in Run Mode, motor runs reverse

 

 

 

 

 

OFF

Inverter is in Stop Mode, motor stops

 

 

 

 

 

 

 

 

 

 

 

 

02

 

 

CF1

 

Multi-speed Select,

 

ON

Binary encoded speed select, Bit 0, logical 1

 

 

 

 

Bit 0 (LSB)

 

OFF

Binary encoded speed select, Bit 0, logical 0

 

 

 

 

 

 

 

 

 

 

03

 

 

CF2

 

Multi-speed Select,

 

ON

Binary encoded speed select, Bit 1, logical 1

 

 

 

 

Bit 1

 

OFF

Binary encoded speed select, Bit 1, logical 0

 

 

 

 

 

 

 

 

 

 

04

 

 

CF3

 

Multi-speed Select,

 

ON

Binary encoded speed select, Bit 2, logical 1

 

 

 

 

Bit 2

 

OFF

Binary encoded speed select, Bit 2, logical 0

 

 

 

 

 

 

 

 

 

 

05

 

 

CF4

 

Multi-speed Select,

 

ON

Binary encoded speed select, Bit 3, logical 1

 

 

 

 

Bit 3 (MSB)

 

OFF

Binary encoded speed select, Bit 3, logical 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Inverter is in Run Mode, output to motor runs at

 

06

 

 

JG

Jogging

 

jog parameter frequency

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

Inverter is in Stop Mode

 

07

 

 

DB

External DC braking

 

ON

DC braking will be applied during deceleration

 

 

 

 

OFF

DC braking will not be applied

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set (select) 2nd Motor

 

ON

The inverter uses 2nd motor parameters for

 

08

 

 

SET

 

 

generating frequency output to motor

 

 

 

 

Data

 

OFF

The inverter uses 1st (main) motor parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for generating frequency output to motor

 

 

 

 

 

 

 

 

 

 

 

 

 