71
“C” Function Defaults
Func.
Code Name Description
Run
Mode
Edit Initial data Units
C147 Logic output 2 operator Applies a logic function to calculate
[LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
U 00
C148 Logic output 3 operand A U 00
C149 Logic output 3 operand B
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no U 01
C150 Logic output 3 operator Applies a logic function to calculate
[LOG] output state,
Three options:
00[LOG] = A AND B
01[LOG] = A OR B
02[LOG] = A XOR B
U 00
C160 Input [1] response time U 1. C161 Input [2] response time U 1. C162 Input [3] response time U 1. C163 Input [4] response time U 1. C164 Input [5] response time U 1. C165 Input [6] response time U 1.
C166 Input [7] response time
Sets response time of each input
terminal, set range:
0 (x 2 [ms]) to 200 (x 2 [ms])
(0 to 400 [ms])
U 1.
C169 Multistage speed/position
determination time
Set range is 0. to 200. (x 10ms) U 0. ms

Input Function Summary Table – This table shows all thirty-one intelligent input functions

at a glance. Detailed description of these functions, related parameters and settings, and

example wiring diagrams are in “Using Intelligent Input Terminals” on page 27.

Input Function Summary Table
Option
Code
Terminal
Symbol Function Name Description
ON Inverter is in Run Mode, motor runs forward
00 FW FORWARD Run/Stop OFF Inverter is in Stop Mode, motor stops
ON Inverter is in Run Mode, motor runs reverse
01 RV Reverse Run/Stop OFF Inverter is in Stop Mode, motor stops
ON Binary encoded speed select, Bit 0, logical 1
02 CF1 Multi-speed Select,
Bit 0 (LSB) OFF Binary encoded speed select, Bit 0, logical 0
ON Binary encoded speed select, Bit 1, logical 1
03 CF2 Multi-speed Select,
Bit 1 OFF Binary encoded speed select, Bit 1, logical 0
ON Binary encoded speed select, Bit 2, logical 1
04 CF3 Multi-speed Select,
Bit 2 OFF Binary encoded speed select, Bit 2, logical 0
ON Binary encoded speed select, Bit 3, logical 1
05 CF4 Multi-speed Select,
Bit 3 (MSB) OFF Binary encoded speed select, Bit 3, logical 0
ON Inverter is in Run Mode, output to motor runs at
jog parameter frequency
06 JG Jogging
OFF Inverter is in Stop Mode
ON DC braking will be applied during deceleration
07 DB External DC braking OFF DC braking will not be applied
ON The inverter uses 2nd motor parameters for
generating frequency output to motor
08 SET Set (select) 2nd Motor
Data OFF The inverter uses 1st (main) motor parameters
for generating frequency output to motor