80
“H” Function Defaults
Func.
Code Name Description
Run
Mode
Edit Initial data Units
H112 PM const Ld(d-axis
inductance, Auto)
0.01-655.35 [mH] U kW
dependent mH
H113 PM const Lq(q-axis
inductance, Auto)
0.01-655.35 [mH] U kW
dependent mH

H116 PM Speed Response 1-1000 [%] U 100 %

H117 PM Starting Current 20.00-100.00 [%] U 70.00[%] %

H118 PM Starting Time 0.01-60.00 [s] U 1.00[s] s

H119 PM Stabilization Constant 0-120 [%] U 100[%] %

H121 PM Minimum Frequency 0.0-25.5 [%] 8.0 [%] %

H122 PM No-Load Current 0.00-100.00 [%] 10.00 [%] %

H123 PM Starting Method Select
00 Normal
01 Initial Magnet Position
Estimation
U 0
-
H131 PM Initial Magnet Position
Estimation 0V Wait Times
0-255 U 10 -

H132

PM Initial Magnet Position
Estimation Detect Wait
Times
0-255 U 10 -
H133 PM Initial Magnet Position
Estimation Detect Times
0-255 U 30 -
H134 PM Initial Magnet Position
Estimation Voltage Gain
0-200 U 100 -