Note Ensure that the drain tube is fully attached to the res- ervoir with a “click.” Partial attachment will not allow ink to drain into the reservoir, which will even- tually cause the service station to overflow with excess ink.

34.Connect the cable to the sensor on the excess ink reservoir (see Fig. 1-11).

35.Connect the supply and takeup cable to the port on the side of the electronics box (see Fig. 1-12).

As you look at the front of the printer, the port is located on the left side of the electronics box, near two other cables that area already connected to ports. Connect the cable firmly to the port.

Supply & takeup cable

Fig. 1-12. Connecting the supply & takeup cable

36.Remove the two Phillips head screws on the front of the vac- uum/pressure system cover, and remove the cover.

1-18

Unpacking and Assembly

Page 32
Image 32
HP 72SR manual Supply & takeup cable